0000
The DC power supply fan stop signal has 
been detected for 5 sec or more even when 
the DC power fan is on.
- Check the connection of the connector.
- Replace the fan.
0001
The IH power supply cooling fan stop 
signal has been detected for 5 sec or more 
even when the IH power supply cooling 
fan is on.
- Check the connection of the connector.
- Replace the fan.
E805
There is a heat discharge fan error/there is a feed fan error.
0001
The heat discharge fan stop signal has been 
detected for 5 sec or more even when the 
heat discharge fan is on.
- Check the connection of the connector.
- Replace the fan.
0002
The feed fan stop signal has been detected 
for 5 sec even when the feed fan is on.
- Check the connection of the connector.
- Replace the fan.
E821
There is a cleaner clogging error.
0001
Clogging of toner inside the cleaner has 
been detected with reference to an 
abnormal rise in the cleaner thermistor.
- Remove the waste toner from inside the 
cleaner.
- Replace the air filter of the heat 
discharge fan.
E824
There is a primary charging cooling fan error.
0001
The primary charging cooling fan stop 
signal has been detected for 5 sec or more 
even when the primary charging cooling 
fan is on.
- Check the connection of the connector.
- Replace the fan.
E840
There is a shutter error.
0001
While the shutter is in operation, the 
sensor signal is not detected and, in 
addition, it is still not detected after 3 
retires.
- Check the connection of the connector 
of the shutter motor and the shutter HP 
sensor.
- check the mounting of the pin used to 
match the shutter gear phase of the fixing 
unit (See descriptions under "Points to 
Note When Mounting the Fixing Roller.")
- Replace the shutter HP sensor and the 
shutter motor.
0002
The interval of ON-OFF detection by the 
sensor in response to shutter operation is 
shorter than a specific time period.
E841
There is an error in the detection of fixing inlet guide connection.
0001
At power-on, the connection of the fixing 
inlet guide solenoid is not detected.
- Check the connection of the connector.
- Replace the solenoid.