Canon galvano gc-251 Benutzerhandbuch

Seite von 88
 
CANON    Digital Galvano Scanner System
 
KP-1SM Series + GC-251 
Users Manual 1.00 
 
 
 
  
54
Command ID 
Command 
Name 
Forced Stop 
Data 
Return 
Value 
0: Command execution successful 
1: Command execution unsuccessful 
Explanation 
This command is used for a stop before the target position during movement by 
Command ID = 8. 
Related 
Command 
Command ID = 8 Data = 0: Movement Start 
 
Command ID 
10 
Command 
Name 
Target Value Setting Mode 
Data 
0: Absolute position 
1: Relative position 
Return 
Value 
0: Command execution successful 
1: Command execution unsuccessful 
Explanation 
This command is used to specify a position coordinate system for setting by “Command 
ID = 20: Target Position Setting.” 
Before setting a target position, this command should be executed. 
Absolute position: Position with the origin as 0 
Relative position: Distance from the current position 
This command should be executed each time a target position is set because its setting 
is not retained after the start of movement. 
 
Related 
Command 
Step movement procedure 
Command ID = 10: Target Value Setting Mode 
   
Command ID = 20: Target Position Setting 
    Command ID = 8 Data = 0: Movement Start