Nokia 9210i Servicehandbuch

Seite von 60
PAMS
Technical Documentation
RAE-5 
3. RF+System Module KL8 
Page 3 – 11
Issue 1 04/02
of the in–phase and quadrature receive and transmit signal paths and also A/D
and D/A conversions of received and transmitted audio signals. Data transmis-
sion between the COBBA_GJP and the MADLinda is implemented using serial
connections. Digital speech processing is executed by the MADLinda ASIC.
External audio is connected to RAE-5 through system connector’s XMIC and
XEAR lines.
Serial connection channels in RAE-5 include IrDA, MBUS, and serial port.
MBUS and serial port have logic level signals which are connected through sys-
tem connector. IR transceiver is next to the system connector at the bottom end
of RAE-5 device.
Block Diagram
LMM
(
DSP
)
SDRAM
XIP MEMORIES
S
ERIAL
F
LASH
PCM
C
ODEC
RFI
COBBA
_
GJP
CCONT
B
ACK
 U
P
B
ATTERY
32
K
H
Z
XTAL
CHAPS
BATTERY
CONNECTOR
SIM
CARD
CONNECTOR
SYSTEM
CONNECTOR
MULTI
MEDIA
CARD
CONNECTOR
UI
CONNECTOR
RF
SYS
RF S
UPPLIES
S
YSTEM
 S
UPPLIES
F
LASH
ARM
925
MPU
S
UBSYSTEM
MADLINDA
PDA 
P
ERIPHERALS
S
YSTEM
 
L
OGIC
I
R
DA
MIC
POWER
AUDIO
_
RFI
UI SIGNALS
SERIAL
INTER-
FACES
EXTERNAL
   AUDIO
CHARGER
EXTERNAL
      RF
RF S
IGNALS
A
UDIO
A
MP
VBB
R
EG.
T
RAFFIC
C
ONTROLLER
V
MMC
R
EG.
V
CORE
R
EG.
A
CC
P
WR
R
EG.
AUDIO
(EARP,
SPEAKER)
HALL
SENSOR
  DOC 
MEMORY
Figure 2.
HW system part block diagram