Functional Description
Modes of Operation
There are three main operation modes in the system when power is on: 
– Running
– Idle
– Deep Sleep
Note that phone can be either on or off in each of power on states.
Figure 3.
Basic Operation Modes of RAE-5 (simplified scheme)
Idle
Running
Deep Sleep
Deep Sleep conditions met
No tasks to run
Power OFF
Reset
Power Up
(VCXO ON)
(VCXO ON)
(VCXO OFF)
Battery voltage
Interrupt
Interrupt
Too low 
Battery
voltage
or
Battery
removed
high enough
Power saving modes are entered under SW control. Returning to running mode
is activated by interrupt (generated internally by MADLinda or from CCONT).
Clocking Scheme
The 26MHz main clock frequency is generated by the  VCTCXO located in the
RF section. This clock is divide in HAGAR to 13MHz.  Clock signal is buffered
to low level sine wave clock signal (RFC) and fed to system HW side. There it
is connected to MADLinda clock input. The MPU within MADLinda can stop the
clock by shutting off the VCTCXO’s supply voltage (VXO) via CCONT.
The CCONT provides a 32kHz sleep clock generated from 32.768kHz quartz
crystal. This clock signal is used internally in CCONT to run the RTC and
routed to MADLinda (SLEEPCLK). Sleep clock is used to run MADLinda when
the main clock is shut down. A backup battery keeps the RTC running if the
main battery is disconnected.
Other clock signals are generated inside MADLinda using PLLs and clock divid-
ers which are controlled by SW. The maximum clock frequency in the MPU side
is 52MHz and in the DSP side 78MHz.