can be controlled individually with 2.8 V logic directly or through control register.
The regulator IC is located in the system block of the transceiver.
Use of the regulators is illustrated in the power distribution diagram Figure 12.
VREF_2 from CCONT IC and RXREF from COBBA IC are used as the refer-
ence voltages for HAGAR RF–IC, VREF_2 (1.5V) for bias reference and
RXREF (1.2V) for RX ADC’s reference.
Control signals
This table shows used control signals for different functions and the typical cur-
rent consumption (VBATT = 3.7 V). All regulators except VXO are switched on
and off using the SYNTPWR control signals. The TX and RX blocks are
switched on and off under HAGAR control. These controls are accessed via se-
rial interface from MADLinda to HAGAR.
Table 13.  Control signals and current consumptions (Measurements fo curremts)
      
VCXOPWR
SYNTHPWR
TXP
Typical current
consumption
Notes
H
H
L
22 mA
Synthesizers
H
H
L
116 mA
RX active
H
H
L
171 mA
TX active except PA
H
H
H
1092 mA
TX active, PL5 to 50 ohm
All regulators which are connected to HAGAR are enabled simultaneously by
SYNTHPWR. In different modes the loads are switched on and off using HA-
GAR’s serial bus.
All control signals are coming from MADLinda and they are 2.8 V logic signals.
List of the needed supply voltages:
Table 14.  Supply voltages       
Voltage source
Supply name
Load
VR1
VXO
VCTCXO, Hagar (VDIGI)
VR2
VRX
HAGAR (VRF_RX, VF_RX)
VR3
VSYN_2
HAGAR (VLO, VPRE)
VR4
VSYN_1
HAGAR (VBB), LNA’s
VR5
VTX
HAGAR (TX modulator)
VR6
COBBA
VREF_2
HAGAR (VB_EXT)–voltage ref.
RXREF
HAGAR (VREF_RX)–voltage ref.
V5V
VCP
VCO, HAGAR (VCP)
TXVGSM (HAGAR)
Antenna switch GSM
TXVDCS (HAGAR)
Antenna switch DCS1800
TXVDET (HAGAR)
Power detector
Battery
VBATT
RF–regulators in CCONT, PA’s