Toshiba MK4006GAH Benutzerhandbuch
Toshiba Corporation Digital Media Network Company
Page 89 of 153
© 2003, Copyright TOSHIBA Corporation All Rights Reserved
WORD 90: Time required for Enhanced Security erase completion
WORD 91: Current Advanced Power Management setting
bit 15-8
Reserved
bit 7-0
Current Advanced Power Management setting set by Set Features Command.
The default value for this WORD is0080h.
WORD 92: Master Password Revision Code
the value of the Master Password Revision Code set when the Master Password was last change. Valid
values are 0001h through FFFEh. A value of 0000h or FFFFh indicates that the Master Password
Revision is not supported.
values are 0001h through FFFEh. A value of 0000h or FFFFh indicates that the Master Password
Revision is not supported.
WORD 93: Hardware configuration test results
bit 15
0 (Fixed)
bit 14
1 (Fixed)
bit 13
1=device detected CBLID- above V
IH
0=device detected CBLID- below V
IL
bit12-8
Device 1 hardware reset result. Device 0 shall clear these bits to zero.
Device 1 shall set these bits as follows :
Device 1 shall set these bits as follows :
12 Reserved.
11
11
0=Device 1 did not assert PDIAG-.
1=Device 1 asserted PDIAG-.
1=Device 1 asserted PDIAG-.
10-9 These bits indicate how Device 1 determined the device number:
00=Reserved.
01=a jumper was used.
10=the CSEL signal was used.
11=some other method was used or the method is unknown.
01=a jumper was used.
10=the CSEL signal was used.
11=some other method was used or the method is unknown.
8
1 (Fixed)
bit 7-0
Device 0 hardware reset result. Device 1 shall clear these bit to zero.
Device 0 shall set these bills as follows:
Device 0 shall set these bills as follows:
7 Reserved.
6
6
0=Device 0 does not respond when Device 1 is selected.
1=Device 0 responds when Device 1 is selected.
1=Device 0 responds when Device 1 is selected.
5
0=Device 0 did not detect the assertion of DASP-.
1=Device 0 detected the assertion of DASP-.
1=Device 0 detected the assertion of DASP-.
4
0=Device 0 did not detect the assertion of PDIAG-.
1=Device 0 detected the assertion of PDIAG-.
1=Device 0 detected the assertion of PDIAG-.
3
0=Device 0 failed diagnostics.
1=Device 0 passed diagnostics.
1=Device 0 passed diagnostics.
2-1
These bits indicate how Device 0 determined the device number:
00=Reserved.
01=a jumper was used.
10=the CSEL signa was used.
11=some other method was used or the method is unknown.
00=Reserved.
01=a jumper was used.
10=the CSEL signa was used.
11=some other method was used or the method is unknown.
0
1 (Fixed)
WORD 94: Current automatic acoustic management value
bit 15-8 Vendor’s recommended acoustic management value
bit 7-0
bit 7-0
Current automatic acoustic management value
This function is not supported. The value for this WORD is 0000h.
WORD 95-99: Reserved
WORD 100-103: Maximum User LBA for 48-bit Address feature set
The value for this WORD is XXXXh.
WORD 104-126: Reserved
WORD 127: Removable Media Status Notification feature set supported
This function is not supported. The value for this WORD is 0000h.
This function is not supported. The value for this WORD is 0000h.