WORD 90:    Time required for Enhanced Security erase completion 
WORD 91:    Current Advanced Power Management setting 
bit 15-8 
Reserved 
bit    7-0 
Current Advanced Power Management setting set by Set Features Command. 
The default value for this WORD is0080h. 
WORD 92:    Master Password Revision Code 
the value of the Master Password Revision Code set when the Master Password was last change.    Valid 
values are 0001h through FFFEh.    A value of 0000h or FFFFh indicates that the Master Password 
Revision is not supported.   
WORD 93:    Hardware configuration test results 
bit 15 
0  (Fixed) 
bit 14 
1  (Fixed) 
bit 13 
1=device detected CBLID- above V
IH
 
0=device detected CBLID- below V
IL
 
bit12-8 
Device 1 hardware reset result. Device 0 shall clear these bits to zero. 
Device 1 shall set these bits as follows : 
12 Reserved. 
11 
0=Device 1 did not assert PDIAG-. 
1=Device 1 asserted PDIAG-. 
10-9  These bits indicate how Device 1 determined the device number: 
00=Reserved. 
01=a jumper was used. 
10=the CSEL signal was used. 
11=some other method was used or the method is unknown. 
1  (Fixed) 
bit 7-0 
Device 0 hardware reset result. Device 1 shall clear these bit to zero. 
Device 0 shall set these bills as follows: 
7 Reserved. 
0=Device 0 does not respond when Device 1 is selected. 
1=Device 0 responds when Device 1 is selected. 
0=Device 0 did not detect the assertion of DASP-. 
1=Device 0 detected the assertion of DASP-. 
0=Device 0 did not detect the assertion of PDIAG-. 
1=Device 0 detected the assertion of PDIAG-.   
0=Device 0 failed diagnostics. 
1=Device 0 passed diagnostics. 
2-1 
These bits indicate how Device 0 determined the device number: 
00=Reserved. 
01=a jumper was used. 
10=the CSEL signa was used. 
11=some other method was used or the method is unknown. 
1  (Fixed) 
 
WORD 94:    Current automatic acoustic management value 
bit 15-8      Vendor’s recommended acoustic management value 
bit 7-0 
Current automatic acoustic management value 
 
    This function is not supported. The value for this WORD is 0000h.   
WORD 95-99:  Reserved 
WORD 100-103:    Maximum User LBA for 48-bit Address feature set 
The value for this WORD is XXXXh. 
 
WORD 104-126:  Reserved 
WORD 127: Removable Media Status Notification feature set supported 