Siemens TC63 Benutzerhandbuch

Seite von 501
TC63 AT Command Set  
7.22 AT^SLCC
s
TC63_ATC_V00.490
Page 169 of 501
5/24/05
Confidential / Draft - Do not copy
 
type of address octect
145
dialing string 
 includes international access code character '+'
129
otherwise
Alphanumeric representation of 
 corresponding to the entry found in phonebook; used character set
should be the one selected with command 
 (Select TE Character Set). 
The maximum displayed length of 
 is 16 characters. If 
 has more than 16 characters, only the
first 15 characters will be displayed. To indicate an overflow, a special character will be used as the 16th char-
acter. This will be a space if the character set selected with 
 is 'GSM', or 'E400' if the character set is
'UCS2'.
Due to time constraints on the necessary evaluation of the phonebook, this parameter may show a default value
during early call phases (e.g. for 
= ''dialing'', ''incoming'' or ''alerting''), even if a phonebook entry is
present for the number concerned. 
Notes
• Teleservices other than voice, data, fax are not fully supported by ME. They are used only in connection with
the handling for 
, and may therefore occur in paramete
 for mobile terminated calls.
• If a URC "
" in verbose mode (see 
) has been buffered while the interface was in dedicated
mode (depending on the settings of 
 parameter 
), each buffered event indicator will be output
as a separate URC after the interface returns to idle mode. 
However, the output will deliver the list of current calls in the "current" state (at the time when the output is
generated), possibly leading to multiple displays of identical list configurations.
• Some parameters of AT command AT+CHLD, as well as some situations where the call status in the network
changes very quickly (e.g. the transition between 
= ''unknown'', ''dialing'' and ''alerting'' for a call to a
reachable subscriber within the registered network) may lead to quasi-simultaneous changes to the states of
one or several calls in the list, possibly leading to multiple displays of identical list configurations.
• If multiple displays of identical list configurations occur, this happens because of intermediate states of the
list, that have already been overridden by new transitions and states. Thus, it is guaranteed that the configu-
ration displayed in such cases is the current configuration at the time of the last display.
• It is adviseable to receive URC "
" on an interface that is not used for call initiation, if verbose output is
configured. If only voice calls are expected, a setting of 
= 0 may be used alternatively in order to
keep the call from blocking the interface.
Examples
EXAMPLE 1
 
<type>
(num)
<alpha>
(str)
^SYSSTART
at+cpin=9999
OK
+CREG: 2
+CREG: 1,''0145'',''0016''
We are now registered
at^sm20=0
command ''ATD'' for an outgoing voice call will termi-
nate immediately with response ''OK''
OK
atd''1234567'';
We start a voice call.
OK
''OK'' response is issued immediately because of set-
ting ''^SM20=0''