Siemens TC63 Benutzerhandbuch

Seite von 501
TC63 AT Command Set  
10.6 AT^SISW
s
TC63_ATC_V00.490
Page 263 of 501
5/24/05
Confidential / Draft - Do not copy
 
10.6
AT^SISW Internet Service Write Data
 write command triggers writing data via the Internet service configured configured with 
TC63 returns the amount of data which can be written: 
 value equal 0 indicates that the TC63 failed to enter online data mode. Details about
the cause of failure is available usin
 value greater than 0 indicates that the TC63 switches into online data mode to transfer
the given number of bytes. 
A URC "
" will be issued if 
• the TC63 is capable to send data after opening the Internet service or 
• less transmission buffer space was confirmed (in 
) than requested (with 
) or 
• or all available data have been transferred. 
This mechanism is designed to avoid polling for free transmission buffer space and thus, free the TA for other
tasks. 
Syntax
Unsolicited Result Code
^SISW: 
Data availability status of the Internet service configured with 
 has changed. 
Parameter Description
Requested number of data bytes to be transmitted via the Internet service configured with 
1...1500
Confirmed number of data bytes to be transmitted via the Internet service configured in 
. This
number may be less or equal to the value requested with 
. 0 value indicates that no data
can be written. 
Test Command
AT^SISW=?
Response(s)
OK 
Write Command
Response(s)
Number of data bytes are expected as specified by 
OK 
ERROR 
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
§
%
%
%
%
%
%
!
!
%
<srvProfileId>
(num)
<reqWriteLength>
(num)
<cnfWriteLength>
(num)