Siemens TC63 Benutzerhandbuch

Seite von 501
TC63 AT Command Set  
18.12 AT^SNFM
s
TC63_ATC_V00.490
Page 423 of 501
5/24/05
Confidential / Draft - Do not copy
 
18.12
AT^SNFM Set microphone audio path and power supply
Th
 read command returns the microphone mute and supply voltage status.
Th
 write command can be used to switch the microphone's audio path (muted / not muted) or to con-
trol the power supply of the VMIC line for the two microphone inputs. 
The microphone can be muted or activated by changing 
 in all audio modes (1 to 6) and during a
voice call only. As an alternative, you can use the 
 command to mute the microphone. 
Syntax
Parameter Description
Microphone mute control parameter. 
Evaluated during voice calls and if 
 is omitted only, e.g. 
=1. 
Command does not depend on audio mode. 
0
Mutes the microphone.
1
(P)
Activates the microphone.
Microphone supply voltage control parameter. Controls the power supply VMIC of the two microphone inputs. 
CME error is given if 
 is not omitted. Enter for example 
=,1 or 
=,2. 
0
Supply voltage is always switched off.
1
Supply voltage is always switched on.
2
(P)
Supply voltage state during voice calls is controlled by the ME. Actual value is
determined by parameter data set of the selected audio mode.
Test Command
AT^SNFM=?
Response(s)
^SNFM: 
(list of supporte
s) , (list of supported 
s) 
OK
Read Command
AT^SNFM?
Response(s)
OK
Write Command
AT^SNFM=
[
][, 
Response(s)
OK 
ERROR 
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS
!
%
%
%
%
%
%
!
%
!
<MicSwitch>
(num)
<MicVccCtl>
(num)