Siemens TC63 Benutzerhandbuch

Seite von 501
TC63 AT Command Set  
4.6 AT+ICF
s
TC63_ATC_V00.490
Page 94 of 501
5/24/05
Confidential / Draft - Do not copy
 
4.6
AT+ICF Serial Interface Character Framing
The command 
 controls the serial interface character framing format and parity used for receiving and
transmitting.
The following settings are supported: 
• 7 bits, even parity, 1 stop bit (
=5,1) 
• 7 bits, odd parity, 1 stop bit (
=5,0) 
• 8 bits, even parity, 1 stop bit (
=2,1) 
• 8 bits, no parity, 1 stop bit (
=3) 
• 8 bits, odd parity, 1 stop bit (
=2,0) 
• 8 bits, no parity, 2 stop bits (
Syntax
Parameter Description
Specifies the character format used for receiving and transmitting.
1
8 data 0 parity 2 stop
2
8 data 1 parity 1 stop
[3]
8 data 0 parity 1 stop
5
7 data 1 parity 1 stop
Specifies the method of calculating the parity bit, if a parity bit is supported by 
If 
 does not support parity, this parameter has to be omitted.
0
odd
1
even
Test Command
AT+ICF=?
Response(s)
+ICF: 
(list of supported 
s), (list of supported 
s)
OK
Read Command
AT+ICF?
Response(s)
+ICF: 
[, 
]
OK
Write Command
AT+ICF=
][
]
Response(s)
OK
ERROR
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
V.250
!
%
%
!
§
§
§
!
%
!
<format>
(num)(&W)(&V)
<parity>
(num)(&W)(&V)