Trimble Outdoors thunderbolt 64057-00-eng Benutzerhandbuch

Seite von 88
Trimble ThunderBolt E GPS Disciplined Clock User Guide     
17
Setting up and Running the ThunderBolt E     
2
8.
The ThunderBolt E automatically begins its self-survey. When this is complete 
and the receiver achieves a position fix, the following information appears in the 
software:
position
time
satellites tracked
GPS receiver status
Note – The receiver sends a health report every few seconds, even if satellites are not being 
tracked.
Data fields 
If the Trimble GPS Monitor program displays a question mark (?) in a data field, the 
receiver has not reported a status for this field. If the question mark stays in place, the 
GPS module may not be communicating with the computer. Check the interface cable 
connections and verify that the serial port selection and settings are set to 9600 baud, 
no parity, 8-bit, and 1 stop/start bit.
If the communication fails, call the Trimble Technical Assistance Center (TAC) at 
1 (800) 767-4822.
Receiver COM port settings
Packet 0xBC sets the ThunderBolt E GPS port characteristics. To change the receiver 
port and then set or request the Input/Output baud rate, data bits, parity, stop bits, and 
flow control parameters, select Configure / Receiver Configuration / Port Configuration 
dialog.
TSIP
The Trimble Standard Interface Protocol (TSIP) consists of command packets and 
report packets. The basic features that are described here include some of the more 
commonly used commands and reports. For a complete description of TSIP, see 
Note – You do not need the packet number when you use the Windows Control Program.
Cable delay compensation
Packet 0x8E-4A enables you to delay or advance the 1 PPS. This may be required to 
compensate for a long cable run. Negative values advance the 1 PPS and compensate 
for cable delay. The 10 MHz and 1 PPS output will remain synchronized.
Note – The factory default is zero.