A      TRIMBLE STANDARD INTERFACE PROTOCOL (TSIP)
1 4 6      Copernicus GPS Receiver
Report Packet 0x4B - Machine/Code ID and Additional Status
The receiver transmits this packet in response to packets 
0x
25 and 
0x
26 and following 
a change in state. In conjunction with Packet 
0x
46, “health of receiver,” this packet 
identifies the receiver and may present status messages. The machine ID can be used 
by equipment communicating with the receiver to determine the type of receiver to 
which the equipment is connected. Then the interpretation and use of packets can be 
adjusted accordingly.
The status codes are encoded into individual bits within the bytes. The bit positions 
and their meanings are listed in the table below.
Report Packet 0x4D - Oscillator Offset
This packet provides the current value of the receiver master oscillator offset in Hertz 
at carrier. This packet contains one single precision number. The receiver sends this 
packet in response to Packet 
0x
2D. The permissible offset varies with the receiver 
unit.
Table A.33
Report Packet 0x4B Data Formats
Byte
Item
Type/
Definition
0
Machine  ID
UINT8
96
1
Status 1
UINT8
See 
2
Status 2
UINT8
Bit 0 set = Superpackets supported
Table A.34
Report Packet 0x4B Bit Positions and Descriptions
Status 1 Bit 
Positions
Meaning if bit value = 1
0 (LSB)
Not used
1
Real-time Clock was not available at power-up.
2
Not used
3
The almanac stored in the receiver is not complete and 
current.
4-7