Trimble Outdoors 58052-00 Benutzerhandbuch
Copernicus GPS Receiver 4 7
INTERFACE CHARACTERISTICS 3
Serial Port Default Settings
The Copernicus GPS Receiver supports two serial ports. The default settings are
provided in the table below.
provided in the table below.
Table 3.4
Copernicus GPS Receiver Serial Port Default Settings
Note – Data Bits, Parity, Stop Bits and Flow Control are not configurable. Only
Protocol and Baud rates are configurable. Detailed descriptions of these protocols
are defined in the Appendices.
Protocol and Baud rates are configurable. Detailed descriptions of these protocols
are defined in the Appendices.
Port
Port
Direction
Direction
Pin #
Protocol
Characteristics
Baud Rate Data Bits
Parity
Stop Bits
Flow Control
A
TXD-A
23
TSIP-Out
38.4 K
8
None
1
NO
RXD-A
21
TSIP-IN
38.4 K
8
None
1
NO
B
TXD-B
24
NMEA-Out
4800
8
None
1
NO
RXD-B
20
NMEA-IN
4800
8
None
1
NO