7-3. Some part of air conditioner does not operate.
7-3-1. Only fan does not run.
7-3-2. Electric heater does not work.
Both for (cooling & electric heating models) and (heat pump model)
• Measure resistance of electric 
heater  winding.
Blown
• Check continuity for thermal 
fuses.
Replace them.
• Measure coil resistance of 
heater relay.
• Check PCB Ass'y.  (Power pack)
(Only for heat pump model)
• Check to see if the circuit of 
heater thermostat is opened or 
closed ?
Fan cannot
be turned.
OK
• Check fan rotation. 
Turn fan gently once or twice by 
hand.
• Check fan casing 
foreign matter on 
inside.
Fan motor burnout 
or foreign matter in 
bearings.
Remove foreign 
matter or repair.
Repair or replace.
• Measure resistance of fan motor 
winding.
• Check fan motor capacitor and
4P-connectors (Socket and Plug).
• Check PCB Ass'y .     (Power pack)
(Only for heat pump model)
31