4.0  CONFIGURATION
 
The Model 3088 (see figure 1) has two configuration modes, DIP switch 
and software.
 
Figure 1. 
 
Model 3088 (3088/D version shown)
 
DIP switch configuration mode is entered by starting the unit with the DIP 
switches in any position other than all OFF or all ON. In DIP switch configu-
ration mode, the DIP switch settings are read at system startup and used to 
configure the unit. Once the unit has started in DIP switch mode it will 
remain in DIP switch mode, and its settings cannot be changed. Console 
commands used to configure the unit will report that the unit is in DIP switch 
configuration and will not change the configuration. Likewise, EOC variables 
cannot be used to configure the device. Also note that changing the DIP 
switch settings while the unit is running will have no effect on the configura-
tion as the DIP switches are only read on startup.
Software configuration mode is entered by starting the unit with the DIP 
switches set to all ON. The system then reads any configuration that might 
have been saved to FLASH. If no configuration has been saved, then the 
factory defaults are loaded. The unit may be further configured by console 
commands or by EOC.