CLEANING AND MAINTENANCE SCHEDULE
Maintaining a clean UltraGrate™ is vital to the safe and efficient operation of the stove.  It is a good idea to verify 
your UltraGrate is clean prior to ignition each time you operate your stove.
 
DAMPER ADJUSTMENT
The Montage™ pellet stove is equipped with a damper which is used to fine tune combustion.  Although every 
unit is test burned and calibrated at the factory, periodic adjustment may be necessary at times to compensate for 
variables such as fuel, venting, altitude, and maintenance intervals.
4
5
IMPORTANT NOTE:
UNPLUG POWER CORD AND ENSURE APPLIANCE IS COLD BEFORE PERFORMING ANY MAINTENANCE WORK.
Above is an example of a pellet 
“clinker”.  This mass of impurities 
can reduce airflow through the 
UltraGrate and create an unsafe 
burning condition.
Properly cleaned UltraGrate:  The 
bars running across the bottom are  
clean and all the openings are clear.
Dirty UltraGrate: The bars run-
ning across the bottom are not 
completely visible.  The UltraGrate 
should be cleaned.  
Opening the damper increases the amount of 
combustion air. This can help increase pellet activity 
in the UltraGrate™ and correct a dark orange or sooty 
flame.  
OPENING THE DAMPER
CLOSING THE DAMPER
Closing the damper decreases the amount of 
combustion air.  This can be a useful adjustment if your 
stove is burning out.  If the damper is closed too much, 
your stove will burn less efficiently and require more 
maintenance.
The damper is located behind the right 
side door.
REFER TO THE “INSTALLATION AND OPERATION 
MANUAL” FOR DETAILED INSTRUCTIONS ON MAKING 
ADJUSTMENTS TO THE DAMPER.