Engineer Setup
The engineer setup option is generally used during installation of alarm sensors or when a sensor is
faulty. Four functions are provided for the engineer.
1.  To put a zone on soak test
2.  To remove a zone from soak test.
Any zones on the system can be placed on soak test. When a zone is on soak test and activated it will
not generate an alarm condition, but the activation will be logged as an event in the system log. If zones
are dynamically displayed on a map, a soak zone will display as a green icon.
3.  To disable a zone
4.  To re-instate a disabled zone.
An engineer can disable any zones on the system. Normally this would be used if a sensor was faulty
and giving false alarms or a zone had been programmed on the system but not yet installed. If zones
are dynamically displayed on a map, a disabled zone will display as a Maroon Icon
5.  To omit a zone from walk test
6.  To re-instate a zone for Walk Test
It may not be possible for site staff to walk test some zones, they may be inaccessible without special
knowledge or equipment, such as equipment failure and tamper alarms. This option is available to omit
and re-instate alarms from the walk test.