7046-137C
Page  5
                   2700-I ACC Wood Insert
R
UL 1777 Insulated Stainless Steel 
Liner or Other Approved Lining System 
Follow Manufacturer’s Instructions 
on Insulation and Support 
For Zero or Other Non-Code Clearances, 
Follow Approved Liner Manufacturer’s Specific 
Insulation Requirements:  Different Clearances 
May Require Different Specifications 
Masonry Chimney Must 
Have Structural Integrity 
UL 1777 Insulated Stainless Steel 
Liner or Other Approved Lining System 
Minimum 8 in. (203mm) Masonry 
Thickness in Front of Smoke Chamber
Damper Plate Removed or 
Fastened in Open Position 
Seal with Non-Combustible Material 
Minimum Clearance in Accordance 
with Insert Listing 
Floor Protection in 
Accordance with Insert 
Listing 
Follow Manufacturer’s 
Instructions for Maximum 
Liner Extension Above 
Chimney 
Maximum 30
 
Degrees 
Offset in Chimney 
Combustible Floor 
Masonry Chimney (Cont’d)
Figure 35.1
NOTE:
  In Canada, this fireplace insert must be installed 
with a continuous chimney liner of a 6 inch (152mm) diam-
eter extending from the fireplace insert to the the top of the 
chimney.  
The chimney liner must conform to the Class  require-
ments of CAN/ULC-S65, Standard for Lining Systems for 
Existing  Masonry  or  Factory-Built  Chimneys  and  Vents, 
or CAN/ULC-S640, Standard for Lining Systems for New 
Masonry Chimneys.
This  insert  conforms  with  the  UL  1482  and  ULC  S628 
(Canada)  in  all  respects,  and  is  approved  to  UL  &  ULC 
safety standards for installation and use within a fireplace 
with a masonry chimney in accordance with NFPA 211 and 
CAN/CSA-B65-01.
NOTE:
 
 
Installation into fireplaces without a permit will 
void the listing.
NOTE:  Generic wood insert shown - not model specific