Juniper Networks T1600 Benutzerhandbuch

Seite von 113
Software release
MultiServices 100: JUNOS 8.5 and later (Type 1)
MultiServices 400: JUNOS 8.5 and later (Type 2)
MultiServices 500: JUNOS 8.5 and later (Type 3)
Supports tunnel services. This feature is included with the PIC and does not require an
individual license.
Individual licenses must be purchased for additional services.
Power requirement:
Type 1: 0.52 A @ 48 V (25 W)
Type 2: 0.69 A @ 48 V (33 W)
Type 3: 0.83 A @ 48 V (40 W)
Description
Active monitoring on:
Type 1: up to 1.6 million flows
Type 2: up to 3.2 million flows
Type 3: up to 3.2 million flows
Hardware features
Support for up to 2000 service sets
Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces
Depending on your JUNOS release and individual licenses, software features for this PIC can
include the features listed in Table 30 on page 72. For more information about the software
features available for services PICs, see the JUNOS Services Interfaces Configuration Guide.
Software features
Status LED, one tricolor:
Off—PIC is offline and it is safe to remove it from the chassis.
Green—PIC is operating normally.
Amber—PIC is initializing.
Red—PIC has an error or failure and no further harm can be done by removing it from
the chassis.
Application LED, one bicolor:
Off—Service is not running.
Green—Service is running under acceptable load.
Amber—Service is overloaded.
LEDs
Table 30: MultiServices PICs Software Features Supported on the T1600 Routing Node
MultiServices 500
MultiServices 400
MultiServices 100
Software Feature
GRE Key
GRE dont-fragment
8.5
8.5
8.5
Stateful firewall with packet inspection: detects SYN
attacks, ICMP and UDP floods, and ping-of-death attacks
8.5
8.5
8.5
Network Address Translation (NAT) for IP addresses
72
MultiServices PICs
T1600 Internet Routing Node PIC Guide