Planning the Installation
Self-Rimming Installation With 
Raised Vent
Only model DR30DI may be installed with a raised vent. Use 
only Dacor raised vent model ERV3015.
A self-rimming countertop configuration is required for raised 
vent installation. On installations with a raised vent, when 
sliding the range into position, it will stop when the rear of the 
control panel or side panels contact the notches toward the 
front of the countertop.
The self-rimming installation of the DR30DI range and 
ERV3015 raised vent create a “built-in” look where the range 
trim overlaps the countertop on both sides and the raised 
vent overlaps the countertop in back. It is also possible, if the 
cabinets are deep enough, to self rim the front of the range 
into the cabinet face immediately behind the control panel 
and door trim or behind the side panels (see side views on 
this and the facing page). The rear range trim will partially 
cover the front of the raised vent chassis in back.
Model DR30DI 
Range and 
ERV3015 
Raised Vent 
With
H
J
K
Countertop self-
rimmed only
20 5/8”  
(52.4 cm)
0” (0 cm) to 
3 1/4” 
(8.3 cm)
0” (0 cm) to 
5 3/8” (13.7 cm)
Countertop and 
Cabinet Front 
Self-Rimmed
,
20 5/8” *  
(52.4 cm)
NA
0” (0 cm) to 
5 3/8” (13.7 cm)
Countertop and 
Cabinet Front 
Self-Rimmed (side 
panels removed)
23 7/8” * 
(60.6 cm)
NA
0” (0 cm) to 
2 1/8” (5.4 cm)
* Cabinet face below countertop must be flush with back of notch 
in countertop.
Countertop height for all self-rimming installations:  
35 7/16” (90.0 cm) minimum, 37 7/16” (95.1 cm) maximum
IMPORTANT: If the 3 1/4 inch side panels are removed, the 
cabinet face must be flush with the back of the control panel.
rear wall recommended
Non-combustible
countertop opening
cabinet opening
below countertop
29 1/4” (74 3 cm)
27 1/2” (69.9 cm)
30” (76.2 cm)
2 9/16” 
(6.5 cm)
10” min.
(25.4 cm)
both sides
Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm) 
Notch countertop
overhang to width of
cabinets
3/8” min. (1.0 cm)
countertop
overhang
raised vent  opening
H
Combustible side
wall above range
below countertop
To cabinet face
To countertop
 front
J K
Model DR30DI/ERV3015 Countertop Self-Rimmed Only, 
3 1/4 Inch Side Panels Not Removed
Top View
Side View
Cabinet face
Countertop
Range trim resting
on countertop
Back of
control
panel
DR30DI[H] range
3/8” min. (1.0 cm)
flat countertop
overhang required 
behind cutout
28 11/16” (72.9 cm)
3 1/4 inch
side panel
ERV3015
raised vent
3/8” min. (1.0 cm) space
required behind ERV3015
chassis to clear stiffener
H
Cutout tolerances: +1/16” (+1.6 mm), -0