  Site Selection and Preparation
This section provides easy step 
by step instructions for selecting a 
location and preparing the site to 
install the fireplace into:
Existing fireplace
• 
New wall construction
• 
Dimplex mantel surround 
• 
kit or custom made mantel 
surround
!
 NOTE 1:  A 15 Amp, 120 
Volt circuit is required.  A 
dedicated circuit is preferred 
but not essential in all cases.  
A dedicated circuit will be 
required if, after installation, 
the circuit breaker trips or 
fuse blows on a regular basis 
when the heater is operating.  
Additional appliances on the 
same circuit may exceed the 
current rating of the circuit 
breaker.
 WARNINg:  Ensure the 
power cord is not installed so 
that it is pinched or against a 
sharp edge and ensure that 
the power cord is stored or 
secured to avoid tripping or 
snagging to reduce the risk of 
fire, electric shock or injury to 
persons.
  Construction and electrical 
outlet wiring must comply 
with local building codes and 
other applicable regulations to 
reduce the risk of fire, electric 
shock and injury to persons.
  Do not attempt to wire your 
own new outlets or circuits.  To 
reduce the risk of fire, electric 
shock or injury to persons, 
always use a licensed 
electrician.
!
 NOTE:  The fireplace insert 
comes completely assembled 
and wired.  some tools may 
be required to prepare the site 
and assembly/install the trim.
  The dimensions of the 
fireplace insert are  30 ¼ inch 
(76.8 cm) wide X 25 ½ inch 
(64.8 cm) high X 11 ½ inch 
(29.2 cm) deep (Figure 1).  
  You should allow 1/4 inch 
(6.4 mm) around the fireplace 
insert for ease of installation.  
This fireplace does not require 
any venting.
 CAUTION:  Clearance for 
air circulation beneath the 
fireplace insert is provided by 
four (4) rubber feet (Figure 1).  
Do not install the fireplace 
insert directly on carpet or 
similar surfaces which may