Zebra Technologies R110XiTM Benutzerhandbuch

Seite von 184
Printer Operation
Adjust Media Sensors
23063L-003 Rev. 2 12/23/04
R110Xi/R170Xi User Guide
37
Adjust Media Sensors
The transmissive sensor consists of two sections: a light source (the lower media sensor) and a 
light sensor (the upper media sensor). The media passes between the two. 
Adjust these sensors only when the printer cannot detect the top of the label. The front panel 
LCD displays 
ERROR CONDITION PAPER OUT
, even though there are labels loaded in 
the printer.
To adjust the upper media sensor for the inside half of the media, complete 
these steps:
1.
Remove the ribbon (if ribbon is used).
2.
Locate the upper media sensor (
). The upper media sensor eye is directly below 
the adjustment screw head.
Figure 27 • Upper Media Sensor Location
3.
Using a Phillips-head screwdriver, slightly loosen the upper media sensor adjustment 
screw.
4.
Using the tip of the screwdriver, slide the upper sensor along the slot to the desired 
position (for non-continuous media with a notch or hole in the media, the sensor must be 
directly above the notch or hole).
5.
Tighten the adjustment screw to secure the upper media sensor.
Note • 
T
he upper media sensor can be positioned along the inside half of the media (the side 
closest to the back of the printer) or the outside half of the media (the side farthest from the 
back of the printer).
1
Upper media sensor adjustment screw
2
Upper media sensor
1
2