Dacor EORS230 Benutzerhandbuch

Seite von 20
6
Installation Specifications
Installation Planning
 WARNING
Observe all governing codes and ordinances during plan-
ning and installation. Contact your local building depart-
ment for further information.
 IMPORtANt
Locate the junction box so that the oven may be easily 
disconnected in the event that it needs to be removed 
from the wall completely for service.
If the oven is not installed level it may deliver poor or 
inconsistent baking results.
A qualified technician must complete the installation of 
this built-in appliance. Proper installation is the respon-
sibility of the customer.
Carefully check the location where the oven is to be 
installed. The oven should be placed for convenient 
access. Make certain that electrical power, meeting 
the specifications on page 4, can be provided in the 
selected location.
Minimum Interior Cabinet Depth: 24” (61.0 cm)
Dacor recommends installing the electrical junction box 
in the one of the locations shown.
Install the junction box in a location that allows the oven 
to be removed from the the cut out for service without 
being disconnected.
Plan the installation so that all minimum clearances are 
met or exceeded. Dimensions shown provide mini-
mum clearances, unless otherwise noted. Be certain 
that proper clearance is provided for the oven door 
when it is in the open position according the Product 
Dimensions.
Cabinet cutout dimensions must be used as indicated.
 
The specified minimum cabinet depth and width must 
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
All contact surfaces between the appliance and the cabi-
net must be solid and level. 
Provide a platform within the cabinet to support the 
oven. It must be installed level and straight. The top 
edge of the platform must be flush with the cut out at 
the front of the cabinet. There are no provisions to level 
the oven after it has been installed. 3/4” (1.9 cm) thick 
plywood is recommended.
Model 
Number
Minimum Cabinet 
Width (N)
Minimum Cut Out 
Width (P)
Minimum Cut out 
Height (R)
EORS127/
MORS127
27”  (68.6 cm)
25 ½” (64.8 cm)
27 5/8” (70.2 cm)
EORS130/
MOCS130
30”  (76.2 cm)
28 ½” (72.4 cm))
EORS136
36” (91.4 cm)
34 ½” (87.6 cm)
27 ¾” (70.5 cm)
EORX227/
MORX227
27” (68.6 cm)
25 ½” (64.8 cm)
49 1/8” (124.8 cm)
EORX230/
MORX230
30” (76.2 cm)
28 ½” (72.4 cm)
Cabinet Dimensions
X = Number of convection ovens, see page 3