Figure 2 - Common Fireplace Locations
Flush with a wall
Through exterior wall 
enclosed in a chase
Corner 
installation
Figure 3 - Fireplace Top Dimensions
Pre-inStALLAtiOn
LOCATION AND SpACE 
REqUIREMENTS
Determine the safest and most efficient loca-
tion for your direct vent fireplace. Make sure 
that rafters and wall studs are not in the way of 
the venting system. Choose a location where 
the heat output is not affected by drafts, air 
conditioning ducts, windows or doors. Figure 
2 shows some common locations. Be aware 
of  all  restrictions  and  precautions  before 
deciding the exact location for your fireplace 
and termination cap.
When deciding the location of your fireplace, 
follow these rules:
•  Do not connect this fireplace venting to a 
chimney flue serving a separate solid-fuel 
burning fireplace or appliance.
•  Due to high temperatures, do not locate this 
fireplace in high traffic areas, windy or drafty 
areas or near furniture or draperies.
•  Proper clearances must be maintained.
•  If your fireplace is to be installed directly on 
carpeting, vinyl tile or any combustible mate-
rial other than wood, it must be installed on a 
metal or wood panel extending the full width 
and depth of the fireplace (see Figure 3).
•  Your  fireplace  is  designed  to  be  used  in 
zero clearance installations. Wall or fram-
ing material can be placed directly against 
any exterior surface on back, sides or top 
of  your  fireplace,  except  where  standoff 
spacers are integrally attached. If standoff 
spacers  are  attached  to  your  fireplace, 
these  spacers  can  be  placed  directly 
against wall or framing material. See fram-
ing details, page 7.
•  When locating termination cap, it is impor-
tant  to  observe  the  minimum  clearances 
shown in Figure 7, page 8.
•  If recessing into a wall, you can avoid extra 
framing by positioning your fireplace against 
an already existing framing member.
•  Do not recess termination cap into a wall 
or siding.
•  You  may  paint  the  termination  cap  with 
450º F  (232º  C)  heat-resistant  paint  to 
coordinate with the exterior finish.
•  There must not be any obstruction such as 
bushes,  garden  sheds,  fences,  decks  or 
utility buildings within 24" from the front of 
the termination cap and the front of outside 
air vent.
•  Do not locate termination cap and outside 
air vent where excessive snow or ice build 
up may occur. Be sure to clear vent ter-
mination area after snow falls to prevent 
accidental  blockage  of  venting  system. 
When using snow blowers, do not direct 
snow towards vent termination area.