CLEARANCES
Minimum clearances to combustibles for the 
fireplace are as follows:
*Back and sides 
1"
Perpendicular walls 
6"
Floor 
0"
Ceiling to louver opening 
42"
Front 
36"
Top of Standoffs 
0"
Vent 
(See venting instructions 
for specific venting 
clearances.)
Combustible material with a maximum thick-
ness of 5/8" may be flush with the top front 
of fireplace.
* For back and sides of fireplace, do not pack 
with insulation or other materials. 1" clearance 
not required at nailing flanges.
NOTICE: This fireplace is intend-
ed for use as supplemental heat. 
Use  this  fireplace  along  with 
your  primary  heating  system. 
Do not install this fireplace as 
your primary heat source. If you 
have a central heating system, 
you may run system’s circulat-
ing blower while using fireplace. 
This will help circulate the heat 
throughout the house.
FRAMING AND FINISHING
Figure 4 shows typical framing of this fireplace. 
Figure 5 shows framing for corner installation. 
All minimum clearances must be met.
If you are using a separate combustible man-
tel piece, refer to Figure 6 for proper instal-
lation height. You can install noncombustible 
mantels at any height above the fireplace.
Note: Noncombustible mantels may discolor!
Pre-inStALLAtiOn
Continued
43
 
1
/
4
"
 (36")
47
 
1
/
4
"
 (42")
41
 
1
/
2
"
 (36")
48
 
1
/
2
"
 (42")
Figure 4 - Framing Clearances with 
Outside Air Flex Duct
Figure 5 - Framing Clearances for Corner 
Installation
Figure 6 - Clearances for Combustible 
Mantels
Ref.
Mantel 
Depth Ref.
Mantel from 
Top of Opening
1
14"
 A
16"
2
12"
 B
14"
3
10"
 C
12"
4
8"
 D
10"
5
6"
 E
8"
6
4"
 F
6"
7
2"
 G
4"
36
 
3
/
8
"
 (36")
43 
3
/
8
" (42")
43" (36"), 50" (42")
42" (36"), 49" (42")
15
 
3
/
4
"
(36")
19" (42")
51
 
3
/
8
"
 (36")
61 
3
/
4
" (42")