 Page 1 of 8
CORTECH DEVELOPMENTS LTD
Microtech Galaxy 500/512 Panel
Introduction
This Datalog 3 software version has been modified to incorporate a driver to communicate with
Ademco Microtech Galaxy alarm panels 500 and 512 (V1.25 or later). The panel must have an
RS232 module fitted (V1.20 or later). The Galaxy panel can be connected directly to a Datalog PC
in local mode where the Datalog has control over the Galaxy panel or remotely via a
communication device such as Adpro VST-10 or DVST, where the Datalog will only monitor the
panel. In both instances, keypad emulation is available to allow programming and set/reset of the
panel from the PC.
Installation
Connections
The alarm system needs to be installed as per manufacturer's requirements with the RS232
module on line 1. A cable should be installed between the Datalog PC Comm Port and the Galaxy
Panel’s RS232 module using the connections in the diagram below.
The default speed for communications to the Galaxy is 9600 baud, at this setting the cable length
should not exceed 15 Metres unless a line driver is used. The default settings for communication
are 9600 Baud, 8 Data bits, 1 Stop Bit and No Parity. For this configuration, the dip switches on the
RS232 module should be:
1,2,3,4,5,7
Off
6,8
On
Communication Baud rate and parity Settings can be changed in the Datalog’s initialisation files to
suit remote configurations.
Module Tamper alarms
The panel is unable to report module tamper alarms directly to the Datalog when directly
connected, to achieve this the tamper switch must be wired to an input on a RIO.
Configuring Panel
Once communication is setup, the Datalog PC will configure the zones on the panel for alarm type
and enter the first 16 characters of the Datalog zone description as the Galaxy zone description.
The system will set all zones to the ‘26=LOG’ alarm type unless requested otherwise. The LOG
alarm type guarantees sending all alarms regardless of the set/unset condition of the panel
.