glen-canyon 720-0026-lp Benutzerhandbuch

Seite von 32
LEAK TESTING        
GENERAL 
Although all gas connections on the grill are leak tested at 
the factory prior to shipment, a complete gas tightness check 
must be performed at the installation site due to possible 
mishandling in shipment, or excessive pressure 
unknowingly being applied to the unit. Periodically check the 
whole system for leaks following the procedures listed 
below. If the smell of gas is detected at anytime you should 
immediately check the entire system for leaks. 
 
BEFORE TESTING 
Make sure that all packing material is removed from the grill 
including the burner tie-down straps. 
DO NOT SMOKE WHILE LEAK TESTING. 
NEVER LEAK TEST WITH AN OPEN FLAME.
 
 
Make a soap solution of one part liquid detergent and one 
part water. You will need a spray bottle, brush, or rag to apply 
the solution to the fittings. For the initial leak test, make sure 
the L.P. cylinder is full. 
 
TO TEST 
Make sure all control valves are in the “OFF” position. Turn 
the gas supply on. Check all connections from the L.P. 
cylinder up to and including the connection to the manifold 
pipe assembly (the pipe that goes to the burners). Soap 
bubbles will appear where a leak is present. If a leak is 
present, immediately turn off the gas supply, tighten any 
leaking fittings, turn gas on, and recheck. Should the gas 
continue to leak from any or all of the fittings, turn off the gas 
supply, and contact our customer service at 
1-800-913-8999. 
 
Only those parts recommended by the manufacturer should 
be used on the grill. Substitution will void the warranty. Do 
not use the grill until all connections have been checked and 
do not leak. 
 
Gas flow check: 
Each grill burner is tested and adjusted at the factory prior to 
shipment; however, variations in the local gas supply may 
make it necessary to adjust the burners, the flames of the 
burners 
Should be visually checked. 
 
Adjustment Bolt 
Locking Nut
 
 
Flames should be blue and stable with no yellow tips, excessive 
noise or lifting. If any of these conditions exist, check to see if the 
air shutter or burner ports are blocked by dirt, debris, spider 
webs, etc. If you have any questions regarding flame stability, 
please call customer service at 1-800-913-8999. 
 
ALWAYS CHECK FOR LEAKS AFTER EVERY LP 
TANK CHANGE 
 
Check all gas supply fittings for leaks before each 
use. It is handy to keep a spray bottle of soapy 
water near the shut-off valve of the gas supply line. 
Spray all the fittings. Bubbles indicate leaks. 
 
Disconnected L.P. cylinders must have threaded valve 
plugs tightly installed, and must not be stored in a 
building, garage or any other enclosed area.
 
The gas must be turned off at the supply cylinder 
when the unit is not in use. 
 
If the appliance is stored indoors the cylinder must be 
disconnected and removed from the appliance. 
Cylinders must be
 
stored outdoors in a 
well-ventilated area out of the reach of children. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14