APPLICATION
Coat all plywood joints, flashings, posts, drains, coves, stairwells
and other irregularities with MULASTICOAT; embed with
Stitchbonded Polyester Fabric; apply additional MULASTICOAT to
saturate fabric, and allow to dry. MULASTICOAT is then applied
over entire substrate in two (2) coats with roller, using firm pres-
sure. (See "COVERAGE" below.)
First coat is allowed to dry to touch, usually 1-2 hours depending
on ambient temperature. Second coat is applied crisscross to first
coat. Allow MULASTICOAT to fully dry before proceeding with
KRETE KOTE/TOP COAT 2000 surfacing.  DO NOT ALLOW
MULASTICOAT TO BE EXPOSED FOR MORE THAN 3 DAYS.
Before proceeding, remove dust from MULASTICOAT with damp
sponge.
First coat of KRETE KOTE/TOP COAT 2000 (see KRETE KOTE
2000 instructions for mixing information) is applied with roller,
squeegee or trowel; fiberglass mesh is immediately embedded
and troweled down firmly. Minimum 2 hours initial cure, longer in
cool weather.
Second coat of KRETE KOTE/TOP COAT 2000 is applied firmly
with trowel. Minimum 2 hours cure time, longer in cool weather. 
Third coat is applied with trowel or hopper gun, depending upon
whether smooth or textured finish is desired. Allow to cure a
minimum of twelve (12) hours before allowing foot traffic and
seventy-two (72) hours minimum for vehicular traffic, longer in 
cool weather.
Not responsible for cracks and delamination caused by
structural movement, improper substrate or application - 
SEE WARRANTY.
Do not bridge expansion or control joints with the Slatex
System. All expansion or control joints must be cut and
cleaned out and filled with approved caulking material.
COLORSEAL 
(Recommended)
Apply two coats of COLORSEAL (Refer to COLORSEAL
“Instructions for use.”) Allow minimum 24 hour cure before allowing
foot traffic and minimum 72 hours before allowing vehicle traffic.
COVERAGE
MULASTICOAT (waterproofing membrane): 40 to 50 sq. ft. per
gallon (2 coats).
KRETE KOTE/TOP COAT 2000 - 65 sq. ft. per bag (3 coats).
(See "PACKAGING AND STORAGE")
COLORSEAL 150 - 200 sq. ft. per gallon (2 coats).
LIMITATIONS
Do not apply any components of the SLATEX SYSTEM when sub-
strate surface temperature is below 50°F, above 100°F, if ambient
temperature is below 50°F and falling, over 100°F and expected to
rise, or if precipitation is expected within a 24 hour period.
PACKAGING AND STORAGE
MULASTICOAT - furnished in 1 and 5 gallon containers, 55 gallon
drums and 275 gallon totes.
KRETE KOTE/TOP COAT 2000 - furnished in 65 lb. bags.
COLORSEAL - furnished in 1 and 5 gallon pails.
Fiberglass Mesh - 475 sq. ft. rolls.
Stitchbonded Plyester Fabric - 10” wide rolls x 324 ft. long.
Store at 40-90°F in Dry Area.
Shelf life is approximately 24 months in unopened bags and
approximately 18 months in unopened pails.
WARRANTY
Materials are guaranteed with respect to uniformity and quality within
manufacturers’ specifications. Seller makes no other warranty,
expressed or implied, regarding the use of its products. Since use of
the product is beyond Seller’s control, the Buyer assumes all risks of
use. Seller’s sole obligation shall be to replace material if found to be
defective. Seller shall not be liable for any damages, injury, loss, direct
or consequential, resulting from use of its products.
TEST METHOD
RESULTS
1. Weatherometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM G23 
2000 Hrs. 
Passed
2. Aging  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM A756D & E
25 Cycles
Passed
3. Bond Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM C297 
P
LYWOOD
C
ONCRETE
Before Aging  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
91 psi
209 psi
After Aging  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM A756D & E
89 psi
218 psi
Failure at: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plywood
Mulasticoat
4. Abrasion Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM D-1242A
1000Rev - 1000Gm Load 
39 mil Loss
5. Percolation Tests  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2” Dia x 48” Water head for 48 Hrs
No Loss
6. Absorption Tests  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM D570
Water Absorption 8.1%
7. Chemical Resistance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM D2299
To most Chemicals and Solvents
8. Freeze Thaw 50 Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM C67
P
LYWOOD
C
ONCRETE
Bond Strength  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
91 psi
202 psi
Failure at: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plywood
Mulasticoat
9. Concentrated Load Test  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 Ib., 5 Cycles
Load Deflection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
.031 in.
Residual Indentation - Final . . . . . . . . . . . . . . . . . . . . . . . . . 
.
018 in.
10. Fire Retardant Roof Test  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UBC 32-7)
Class B
11. Anti-Skid Test (Leather and Rubber)  . . . . . . . . . . . . . . . . . . . . ASTM C1028
D
RY
W
ET
Factor of Static Friction. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.87 - .88
.75 - .79
Factor of Sliding Friction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 
.52 - .77
.67 - .72
12. Wind Uplift Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Factory Mutual 1-52
Passed
TEST DATA— SLATEX SYSTEM 
(Above Grade)
The Coating of the Future…Today
MC0406
MULTICOAT
®
CORPORATION
West Coast
Toll Free: (877) 685-8426
(949) 888-7100  Fax (949) 888-2555
Website: www.multicoat.com
E-mail: info@multicoat.com
MULTICOAT
®
PRODUCTS, INC.
East Coast
Toll Free: (800) 660-6729
(304) 586-0616  Fax (304) 586-0620
Website: www.multicoat.com
E-mail: info@multicoat.com
Available Through: