Puls CS3.241 Power Supply Техническое Руководство
CS3.241
C–Series
24V, 3.3A, S
INGLE
P
HASE
I
NPUT
September. 2007 / Rev. 1.1 DS-CS3.241-EN
All parameters are specified at 24V, 3.3A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
All parameters are specified at 24V, 3.3A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
10/21
15. EMC
The CE mark is in conformance with EMC directive 89/336/EC, 93/68/EC and 2004/108/EC and the low-voltage directive
(LVD) 73/23/EWG. A detailed EMC Report is available on request.
(LVD) 73/23/EWG. A detailed EMC Report is available on request.
EMC Immunity
EN 61000-6-2, EN 61000-6-1
Generic standards
Electrostatic discharge
EN 61000-4-2
Contact discharge
Air discharge
Air discharge
8kV
15kV
15kV
Criterion A
Criterion A
Criterion A
Electromagnetic RF field
EN 61000-4-3 80MHz-2.7GHz
10V/m
Criterion
A
Fast transients (Burst)
EN 61000-4-4
Input lines
Output lines
Output lines
4kV
2kV
2kV
Criterion A
Criterion A
Criterion A
Surge voltage on input
EN 61000-4-5
L Æ N
N / L Æ PE
N / L Æ PE
2kV
4kV
4kV
Criterion A
Criterion A
Criterion A
Surge voltage on output
EN 61000-4-5
+ Æ -
+ / - Æ PE
+ / - Æ PE
500V
500V
500V
Criterion A
Criterion A
Criterion A
Conducted disturbance
EN 61000-4-6
0,15-80MHz
10V
Criterion A
Mains voltage dips
EN 61000-4-11
0% of 100Vac
40% of 100Vac
70% of 100Vac
0% of 200Vac
70% of 100Vac
0% of 200Vac
40% of 200Vac
70% of 200Vac
70% of 200Vac
0Vac, 20ms
40Vac, 200ms
70Vac, 500ms
0Vac, 20ms
80Vac, 200ms
140Vac, 500ms
40Vac, 200ms
70Vac, 500ms
0Vac, 20ms
80Vac, 200ms
140Vac, 500ms
Criterion B *)
Criterion C
Criterion A
Criterion A
Criterion A
Criterion A
Criterion C
Criterion A
Criterion A
Criterion A
Criterion A
Voltage interruptions
EN 61000-4-11
0Vac, 5000ms
Criterion C
Input voltage swells
PULS internal standard
300Vac, 500ms
Criterion A
Powerful transients
VDE 0160
Over entire load
range
range
750V, 1.3ms
Criterion A
Criterions:
A: Power supply shows normal operation behavior within the defined limits.
B: The power supply continuous to operate as intended after the test. No degradation of performance or loss of function occur,
when the power supply is used as intended. During the test, degradation of performance is however possible.
C: Temporary loss of function is possible. Power supply might shut-down and restarts by itself. No damages or hazards for the
power supply will occur.
*) Below 2.8A criterion A is fulfilled
B: The power supply continuous to operate as intended after the test. No degradation of performance or loss of function occur,
when the power supply is used as intended. During the test, degradation of performance is however possible.
C: Temporary loss of function is possible. Power supply might shut-down and restarts by itself. No damages or hazards for the
power supply will occur.
*) Below 2.8A criterion A is fulfilled
EMC Emission
EN 61000-6-3, EN 61000-6-4
Generic standards
Conducted emission
EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22
Class B, input lines
EN 55022
Class A, output lines
Radiated emission
EN 55011, EN 55022
Class B
Harmonic input current
EN 61000-3-2
Fulfilled (Class A)
Voltage fluctuations, flicker EN
61000-3-3
Fulfilled
This device complies with FCC Part 15 rules.
Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Switching frequency
50kHz to 450kHz
Input voltage and load dependent