Puls CS3.241 Power Supply Guia De Especificação

Página de 21
 
 
 
CS3.241 
 
  CSeries 
24V, 3.3A, S
INGLE 
P
HASE 
I
NPUT
 
 
 
September. 2007 / Rev. 1.1  DS-CS3.241-EN 
All parameters are specified at 24V, 3.3A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
10/21 
 
15. EMC 
 
The CE mark is in conformance with EMC directive 89/336/EC, 93/68/EC and 2004/108/EC and the low-voltage directive 
(LVD) 73/23/EWG. A detailed EMC Report is available on request. 
 
 
EMC Immunity 
EN 61000-6-2, EN 61000-6-1   
Generic standards 
 
Electrostatic discharge  
EN 61000-4-2 
Contact discharge 
Air discharge 
8kV 
15kV 
Criterion A 
Criterion A 
  Electromagnetic RF field 
EN 61000-4-3 80MHz-2.7GHz 
10V/m 
Criterion 
 
Fast transients (Burst) 
EN 61000-4-4 
Input lines 
Output lines 
4kV 
2kV 
Criterion A 
Criterion A 
 
Surge voltage on input 
EN 61000-4-5 
L Æ N 
N / L Æ PE 
2kV  
4kV 
Criterion A 
Criterion A 
 
Surge voltage on output 
EN 61000-4-5 
+ Æ - 
+ / - Æ PE 
500V 
500V 
Criterion A 
Criterion A 
  Conducted disturbance 
EN 61000-4-6 
0,15-80MHz 
10V 
Criterion A 
 
Mains voltage dips 
EN 61000-4-11 
0% of 100Vac
 
40% of 100Vac 
70% of 100Vac  
0% of 200Vac
 
40% of 200Vac 
70% of 200Vac 
0Vac, 20ms 
40Vac, 200ms 
70Vac, 500ms 
0Vac, 20ms 
80Vac, 200ms 
140Vac, 500ms 
Criterion B *) 
Criterion C 
Criterion A 
Criterion A 
Criterion A 
Criterion A 
  Voltage interruptions 
EN 61000-4-11 
 
0Vac, 5000ms 
Criterion C 
  Input voltage swells 
PULS internal standard 
 
300Vac, 500ms 
Criterion A 
 
Powerful transients 
VDE 0160 
Over entire load 
range 
750V, 1.3ms 
Criterion A 
Criterions: 
A:  Power supply shows normal operation behavior within the defined limits.  
B:  The power supply continuous to operate as intended after the test. No degradation of performance or loss of function occur,  
      when the power supply is used as intended.  During the test, degradation of performance is however possible. 
C:  Temporary loss of function is possible. Power supply might shut-down and restarts by itself. No damages or hazards for the  
      power supply will occur. 
*) Below 2.8A criterion A is fulfilled 
 
  EMC Emission 
EN 61000-6-3, EN 61000-6-4 
Generic standards 
  Conducted emission  
EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22 
Class B, input lines 
   
EN 55022 
Class A, output lines  
  Radiated emission 
EN 55011, EN 55022 
Class B 
  Harmonic input current 
EN 61000-3-2  
Fulfilled (Class A) 
  Voltage fluctuations, flicker EN 
61000-3-3 
 
Fulfilled 
 
This device complies with FCC Part 15 rules.  
Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may cause undesired operation. 
 
 
  Switching frequency 
 
 
   
50kHz to 450kHz 
Input voltage and load dependent