Puls ML15.121 Power Supply Техническое Руководство

Seite von 23
 
 
ML15.121
 
 
MiniLine-2 
 
12V,
 
1.3A,
 
S
INGLE 
P
HASE 
I
NPUT
 
 
 
6.  O
UTPUT
 
 
Output voltage 
nom. 
12V 
 
Adjustment range 
min. 
12-15V 
guaranteed 
 
max. 
16V *) 
at clockwise end position of potentiometer 
Factory setting 
 
12.0V  
 ±0.2%, at full load, cold unit 
Line regulation 
max. 
10mV 
85-264Vac 
Load regulation 
max. 
100mV 
static value, 0A Æ 1.3A 
Ripple and noise voltage 
max. 
75mVpp 
20Hz to 20MHz, 50Ohm 
Output capacitance 
typ. 
1 650μF 
 
Output current  
nom. 
1.3A 
at 12V, see Fig. 6-1
 
nom. 
1.0A 
at 15V, see Fig. 6-1
Output power 
nom. 
15W 
 
Short-circuit current 
min. 
hiccup mode, see Fig. 6-2
hiccup 
*) 
This is the maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. It is not a 
guaranteed value which can be achieved. The typical value which can be achieved by turning the potentiometer to the clock-wise end 
position is 15.7V. 
 
 
Fig. 6-1   Output voltage vs. output current, 
typ. 
 
Fig. 6-2   Hiccup mode; output current at 
shorted output, 230Vac, typ. 
 
Output Voltage
0
0
2
4
6
16V
8
10
12
2.0A
1.0
0.6
0.2
1.4
0.8
0.4
1.2
14
1.8
Adjustment
Range
Output Current
Continuous
Hiccup Mode
 
 
Output
Current
0
1.7A
60ms
t
240ms
240ms
 
 
 
Peak current capability (up to several milliseconds) 
The power supply can deliver a peak current which is higher than the specified short term current. This helps to start 
current demanding loads or to safely operate subsequent circuit breakers. 
The extra current is supplied by the output capacitors inside the power supply. During this event, the capacitors will be 
discharged and causes a voltage dip on the output. Detailed curves can be found in chapter 22.1
Peak current voltage dips  
typ. 
from 12V to 7.8V 
at 2.6A for 50ms, resistive load 
 
typ. 
from 12V to 5.2V 
at 6.5A for 2ms, resistive load 
 
typ. 
from 12V to 2.0V 
at 6.5A for 5ms, resistive load 
 
Mar. 2013 / Rev. 2.1  DS-ML15.121-EN 
All parameters are specified at 12V, 1.3A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
6/23