To replace the SLA battery:
unplug the battery connector
loosen the 3 bracket bolts shown in the diagram to the right
(do not remove the bolts; they are captive to the bracket) 
disconnect the wiring harness from the old SLA battery 
connect the wiring harness to the new battery paying
careful attention to the polarity: the red wire goes to the
positive battery terminal and the black wire goes to the
negative battery terminal.  
Place the new battery in the Gateway and plug the harness
back into the Gateway battery connector; observe the red
reverse-polarity indication light: it should be off.
If external power is present, the SLA status LEDs should
indicate that the battery is charging.
When shipping the Gateway or storing it for extended periods, the
SLA should be disconnected from the Gateway.
Warning: SLA batteries are capable of supplying large amounts of power and can be dangerous
if short-circuited.  The Gateway circuitry includes a self-resetting fuse that automatically
limits the battery current in the event of a short circuit, however care should be
exercised while handling SLA batteries.
Lithium Backup Battery
If an extended power outage
depletes the SLA battery, a
non-rechargeable Lithium
battery keeps the Gateway
operating its mesh and
collecting reports and alarms
for up to several months.
When operating on Lithium
backup power, most of the
Gateway's subsystems are
shut down to conserve power;
only the critical mesh
networking and storage
subsystems are powered.
Moreover, the Gateway
operates the mesh at a
reduced duty-cycle while
operating on battery power.
The Lithium backup battery is
a 3.6v 13AH spiral-wound
Lithium Thionyl battery model
number ER34615M; please
note that the 'M' is important
and non-M batteries should
not be used.  Lithium batteries operate from -40 to +85C making them capable of supplying
emergency power for the gateway over its entire operating range.
Copyright 2011, Axiometric, LLC 