Axiometric LLC MS2E Benutzerhandbuch

Seite von 17
Gateway - QSG
DC Power Requirements
The Gateway typically consumes less than 3W of power with maximum DC
power consumption of 15W.  The minimum input voltage is 12v for proper
operation of the Gateway SLA charger. If the SLA backup battery is not
required, lower input voltages may be used with a minimum external input
voltage of 8v.  The external power LEDs in the external status panel provide
visual feedback indicating that the power levels are sufficient; if the voltage is
too low or too high, the external power error red LED illuminates; otherwise,
between one and 4 green LEDs illuminate to indicate the voltage is in the
adequate range.
An external 12vdc supply should be capable of supplying at least 1.5A to meet
the maximum power requirements while accounting for cable and other losses;
a 24vdc supply need only supply 750mA. Note that when supplying power via
PoE (over a CAT5 cable), the maximum current allowed is 1.154A.
Accordingly, an 18-24vdc or higher power supply is recommended when
supplying power via PoE.
Note that long cable runs will reduce the voltage delivered to the Gateway;
accordingly a higher voltage power source may be needed to compensate for
the cable loss. 
Each 100 feet of CAT5 adds 1.2-ohms of resistance which reduces the voltage delivered to the
Gateway. For a Gateway to operate at maximum power at 18vdc/833mA, the power source
voltage would need to be increased to 19vdc/833mA to compensate for the 1v lost in the 100'
CAT5 cable. Alternatively, the power source current could be increased to 18vdc/883mA which
would deliver the same amount of power but at a lower voltage (17vdc/883mA) to the Gateway.
When lowering the voltage delivered to the Gateway, be sure to observe the maximum current
limits of the cable (1.154A max for CAT5).
PoE  (Power over Ethernet)
When power is supplied over pins 4,5 and 7,8 (two pairs) of a CAT5 Ethernet connection (PoE);
this arrangement is commonly referred to as “passive PoE”.  When using Power over Ethernet, a
MeshPlus Passive PoE injector must be used.  The PoE injector voltage is lower than many IT
router PoE devices; attaching the Gateway to other PoE power devices which commonly supply
48vdc can damage the Gateway.  Placing the Axiometric PoE injector between the Gateway and
other PoE equipment will prevent harm to the Gateway and will not affect the other PoE
equipment.
The External DC power input has extensive voltage surge protection as well as over-current and
over-voltage protection.  If the input voltage exceeds 30v, a MOV will trip a self-resetting fuse to
protect the Gateway from damage.
Copyright 2011, Axiometric, LLC 