Oscilloscope Operations   
 
  Screen Layout and Operations 
124 
 
Probe   
A  probe  is  any  transducer,  measuring  device  or  other  accessory  that  you 
connect to an input channel of your MaxiScope module.   
Reference Waveform 
A Reference Waveform is a copy of an existing signal waveform saved as a 
reference.  It  can  be  retrieved  to  display  as  a  comparative  reference  to 
examine a live signal. Up to 4 reference waveforms can be saved. 
Figure 16-5 Ref. Waveform Save Window
 
 
To create a Reference Waveform
1.  Tap the 
Tool button in the Top Menu. 
2.  Select 
Save Ref. in the dropdown menu. 
3.  Select the channel to which the desired waveform belongs. 
4.  Name the reference waveform by selecting R1, R2, R3 or R4 in the 
popup window. 
5.  Tap on the
 
Yes icon to save, or No
 
icon to cancel. 
Recall Reference 
The saved reference waveforms can be retrieved by clicking Recall Ref in the 
dropdown menu of the Tool button.     
 
To recall reference waveforms: 
1.  Tap 
Tool button on the Top Menu. 
2.  Select 
Recall Ref in the dropdown menu and a popup window  will 
display. Available reference waveform items are highlighted in blue. 
3.  Select  the  desired  reference  waveform  by  ticking  the  check  box 
alongside.   
4.  Tap 
Yes  and  the  selected  reference  waveform  will  appear  on  the 
scope screen.