Oscilloscope Operations   
 
  Screen Layout and Operations 
126 
 
16.4.3 Measurement Grid 
The 2 control features - Voltage per division and Time per division 
– enable 
the users to adjust the scope settings to suit the particular test measurement. 
Figure 16-7 Sample Measurement Grid 
 
Voltage per division 
– shown down the left side of the screen, referred to 
as the Y-axis
 
 
Time per division 
– shown along the bottom of the screen, referred to as 
the X-axis 
Multiple Scope Channels 
The  MaxiScope  software  features  multiple  channel  display  which  enables 
more  than  one  waveform  to  be  displayed  at  the  same  time.  It  is  useful  for 
making  comparisons  among  different  signals.  The  voltage  per  division  for 
each  channel  is  adjusted  individually  while  the  time  base  per  division is the 
same for all channels.   
 
To adjust the voltage scale   
1. 
Tap the specific Y-axis of the corresponding channel to enable scale 
adjustment. The  selected  Y-axis is  highlighted  with thicker  dividing 
line. 
2. 
Adjust  the  voltage  scale  of  the  selected  channel  with  the  typical 
2-finger zoom gestures. 
3. 
The 0 volts is hinted with a pointer reference line. Slide the pointer