ION®-E Series Low Power Carrier Access Point Installation Guide
M0201AAC
Page 36
© February 2018 CommScope, Inc.
 Installing CAP Ls
 
4
Follow the steps in one of the following sections that apply to securing the desired mounting bracket to
the CAP L:
5
Use four 5/16-inch or M8 lag screws (or whatever screw type is appropriate for the material to which the
CAP L is to mounted on) to mount the CAP L to the ceiling.
6
Follow the steps in
if grounding is required or preferred.
7
Follow the steps in
(Optional) Ground the CAP L
Follow the steps below to ground the OPA only if grounding is required in your locality or if the installation
plans require the CAP L be grounded. The different CAP L installation procedures will tell you when to ground
the CAP L.
NOTE:
The CAP L is equipped with an M6 grounding stud located on the back of the unit; however, 
grounding is not necessary. CAP Ls are classified as low-voltage devices and do not have internal 
power supplies. CommScope recommends checking your local and national electrical codes to 
determine if grounding is a requirement. 
1
Obtain a length of #18 AWG (1.00 mm)
insulated stranded copper wire for use as
a chassis-grounding wire.
2
Terminate one end of the wire with a ring
terminal.
3
Locate the chassis-ground stud at the rear
of the CAP L enclosure.
4
Remove the Keps nut from the
chassis-ground stud.
5
Attach the ring end of the wire to the
chassis ground stud, as shown in the
graphic to the right.
6
Use the Keps nut removed in
to
secure the ground wire to the
chassis-ground stud.
7
Route the free end of the chassis
grounding wire to an approved (per local
code or practice) earth ground source.
Ground
stud