Good Way Technology Co. Ltd. TD11000Z2 Benutzerhandbuch

Seite von 3
User's Manual   
Introduction 
Z-Wave Roller Shutter Controller is an ideal for the remotely electric 
motor controller. It is used to control the motors of rollers, shades, 
blinds, venetian blinds and similar sun shade, which are single phase 
AC powered. The module can be controlled either through a Z-Wave 
network  or  through  the  wall  switch,  and  measures  power 
consumption of motor. 
Z-Wave Roller Shutter needs to motor calibration before use, please 
refer to CONFIGURATION command class parameter 0x01. Z-Wave 
Roller  Shutter’s  positioning  calibration  does  not  apply  to  motor 
without  obstacle  detection,  using  this  function  may  cause 
unpredictable problems, please make sure your motor has obstacle 
detection function before positioning calibration. 
 
Package Contents 
■ Z-Wave Roller Shutter Controller   
x1 
■ User Manual 
x1 
 
Command Class
 
Device Information   
GENERIC_TYPE_SWITCH_MULTILEVEL   
SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
 
z-wave protocol Command Class Node Info 
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 
COMMAND_CLASS_VERSION_V3 
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 
COMMAND_CLASS_POWERLEVEL_V1 
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 
COMMAND_CLASS_CONFIGURATION_V1 
COMMAND_CLASS_ASSOCIATION_V2 
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 
COMMAND_CLASS_SWITCH_BINARY_V1 
COMMAND_CLASS_METER_V3 
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 
COMMAND_CLASS_SUPERVISION_V1 
COMMAND_CLASS_Transport_Service_V2 
COMMAND_CLASS_SECURITY_V1 
COMMAND_CLASS_SECURITY_2_V1 
The Below listed Command Class are all supported the S
ecurity S2 
COMMAND_CLASS_VERSION_V3 
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 
COMMAND_CLASS_POWERLEVEL_V1 
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 
COMMAND_CLASS_CONFIGURATION_V1 
COMMAND_CLASS_ASSOCIATION_V2 
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 
COMMAND_CLASS_SWITCH_BINARY_V1 
COMMAND_CLASS_METER_V3 
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 
COMMAND_CLASS_SUPERVISION_V1 
 
Detailed description of each command class 
【ZWAVEPLUS INFO command class】 
The  Z-Wave  Plus  Info  Get  Command  is  used  to  get  additional 
information of the Z-Wave Plus device in question. 
【VERSION command class】 
The  user  can  enquire  the  version  of  the  unit  using  VERSION_GET 
command.  It  will  return  VERSION_REPORT  Command.  Version 
Report Command: 
[Command  Class  Version,  Version  Report,  Z-Wave  Library  Type,  Z-
Wave  Protocol  Version,  Z-Wave  Protocol  Sub  Version,  Application 
Version, Application Sub Version] 
【MANUFACTURER SPECIFIC command class】 
The user can use the Manufacturer Specific Get Command to request 
manufacturer 
specific 
information 
from 
another 
node. 
Manufacturer Specific Report Command: 
[Command  Class  Manufacturer  Specific,  Manufacturer  ID  1, 
Manufacturer ID 2, Product Type ID 1, Product Type ID 2, Product ID 
1, Product ID 2] 
【DEVICE RESET LOCALLY command class】 
The  Device  Reset  Locally  Command  Class  is  used  to  notify  central 
controllers  that  a  Z-Wave  device  is  resetting  its  network  specific 
parameters. 
【POWERLEVEL command class】 
The  Power  level  Command  Class  defines  RF  transmit  power 
controlling commands useful when installing or testing a network. 
The commands make it possible for supporting controllers to set/get 
the RF transmit power level of a node and test specific links between 
nodes with a specific RF transmit power level. 
【BASIC command class】 
Control the roller shutter to be opened or closed after receiving the 
BASIC_SET command.   
To be opened:   
[Command Class Multilevel, Multilevel Set, Value = 0xFF] 
To be closed:   
[Command Class Multilevel, Multilevel Set, Value= 0x00] 
To be the percentage of full opened position: 
[Command Class Multilevel, Multilevel Set, Value = 0x01~0x63] 
【SWITCH MULTILEVEL command class】 
Control the roller shutter to be opened, closed, stopped or be the 
percentage of full opened position after receiving the SWITCH 
MULTILEVEL command. 
To be opened:   
[Command Class Multilevel, Multilevel Set, Value = 0xFF] 
To be closed:   
[Command Class Multilevel, Multilevel Set, Value= 0x00] 
To be the percentage of full opened position: 
[Command Class Multilevel, Multilevel Set, Value = 0x01~0x63] 
To be stopped: 
[Command Class Multilevel, 
SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE] 
【CONFIGURATION command class】 
This class is used for setting certain vendor specific configuration 
variables. See the following table for configuration variables: 
Parameter  Name 
Size 
(byte) 
Range  Default 
value 
Description 

(0x01) 
Positioni
ng 
Calibratio
0 - 1 
0: Disable 
1: Executing 
calibration 

(0x02) 
External 
switch 
Protectio
0 - 1 
0: Enable external 
switch 
1: Disable external 
switch 

(0x03) 
When 
the door 
is 
opened, 
set the 
delay 
time for 
automati
c closing. 
0 - 
32767 
0: Disable automatic 
closing 
1 - 32767: The door 
will be closed 
automatically in 1 - 
32767sec 

(0x04) 
When 
the door 
is open, 
set the 
delay 
time for 
automati

notificati
on. 
0 - 
32767 
0: Disable automatic 
notification 
1 - 32767: The 
notification will be 
sent automatically in 
1 - 32767sec 

(0x05) 
Set the 
operatio
n mode 
0 - 1 
0: Roller Shutter 
1: Venetian 
(up/down and slate 
rotation) 

(0x06) 
Set the 
angle of 
blinds 
0 - 6 
Angles of blinds 
0:0∘ 
1:30∘ 
2:60∘ 
3:90∘ 
4:120∘ 
5:150∘ 
6:180∘ 

(0x07) 
Set the 
slats 
turning 
time 
0 - 127  15   
(1.5sec
0:Disable. 
1 - 127: 0.1 - 12.7 sec 

(0x08) 
Set the 
delay 
time to 
start the 
motor up 
to the 
blade 
0 - 127  0 
0:No offset time 
1 - 127: 0.1 - 12.7 sec 

(0x09) 
Set the 
delay 
time to 
start the 
motor 
down to 
the blade 
0 - 127  0 
0:No offset time 
1 - 127: 0.1 – 12.7 sec 
10 
Set the  1 
0 - 100  0 
0:Disabled 
(0x0A) 
power 
changed 
percenta
ge to 
send the 
power 
report 
1 - 100: 1% - 100% 
11 
(0x0B) 
Set the 
time 
interval 
of 
reporting 
watts in 
seconds 
0, 
60 - 
32767 
300 
sec 
0:Disable 
60 - 32767:   
60 - 32767sec 
12 
(0x0C) 
Set the 
time 
interval 
of 
reporting 
KWH in 
seconds 
0, 
60 - 
32767 
3600 
0:Disable 
60 - 32767:   
60 
- 32767sec 
【ASSOCIATION command class】 
The device can be set 1 auto-report ID in Group 1.   
The device sends an unsolicited command to the configured 
destinations when triggered by an event. 
Group1:"Lifeline" : 
【ASSOCIATION GRP INFO command class】 
The purpose of the Association Group Information (AGI) Command 
Class is to allow a device to report the capabilities of each 
association group supported by the device. 
【SWITCH_BINARY command class】 
Control the roller shutter to be opened or closed after receiving the 
SWITCH BINARY command. 
To be opened: 
[Command Class SWITCH_BINARY, Set Value = 0xFF] 
To be closed:   
[Command Class SWITCH_BINARY, Set Value = 0x00] 
【METER command class】 
The Meter Command Class is intended for Z-Wave enabled devices 
capable of reporting energy measurements in addition to any main 
functionality  or  features  e.g.  an  appliance  module  reporting  the 
current consumption of the connected load.  The Meter command 
class not support V1&V2 version. And it will take about 3 seconds to 
show the meter report on the request sending device. 
【FIRMWARE UPDATE META DATA command class】 
Support OTA (On-The-Air) firmware update function. 
【COMMAND_CLASS_SECURITY_V1】 
【COMMAND_CLASS_SECURITY_2_V1】 
This device is a security enabled Z-Wave Plus product that is able to 
use  encrypted  Z-Wave  Plus  messages  to  communicate  to  other 
security enabled Z-Wave Plus products. 
 
 
Product Overview 
Product Dimensions