Good Way Technology Co. Ltd. TD11000Z2 Manuel D’Utilisation
User's Manual
Introduction
Z-Wave Roller Shutter Controller is an ideal for the remotely electric
motor controller. It is used to control the motors of rollers, shades,
blinds, venetian blinds and similar sun shade, which are single phase
AC powered. The module can be controlled either through a Z-Wave
network or through the wall switch, and measures power
consumption of motor.
Z-Wave Roller Shutter needs to motor calibration before use, please
refer to CONFIGURATION command class parameter 0x01. Z-Wave
Roller Shutter’s positioning calibration does not apply to motor
without obstacle detection, using this function may cause
unpredictable problems, please make sure your motor has obstacle
detection function before positioning calibration.
Package Contents
■ Z-Wave Roller Shutter Controller
x1
■ User Manual
x1
Command Class
Device Information
GENERIC_TYPE_SWITCH_MULTILEVEL
SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
z-wave protocol Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_Transport_Service_V2
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_Transport_Service_V2
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1
The Below listed Command Class are all supported the S
ecurity S2
ecurity S2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_SUPERVISION_V1
Detailed description of each command class
【ZWAVEPLUS INFO command class】
The Z-Wave Plus Info Get Command is used to get additional
information of the Z-Wave Plus device in question.
【VERSION command class】
The user can enquire the version of the unit using VERSION_GET
command. It will return VERSION_REPORT Command. Version
Report Command:
[Command Class Version, Version Report, Z-Wave Library Type, Z-
Wave Protocol Version, Z-Wave Protocol Sub Version, Application
Version, Application Sub Version]
【MANUFACTURER SPECIFIC command class】
The user can use the Manufacturer Specific Get Command to request
manufacturer
specific
information
from
another
node.
Manufacturer Specific Report Command:
[Command Class Manufacturer Specific, Manufacturer ID 1,
Manufacturer ID 2, Product Type ID 1, Product Type ID 2, Product ID
1, Product ID 2]
【DEVICE RESET LOCALLY command class】
The Device Reset Locally Command Class is used to notify central
controllers that a Z-Wave device is resetting its network specific
parameters.
【POWERLEVEL command class】
The Power level Command Class defines RF transmit power
controlling commands useful when installing or testing a network.
The commands make it possible for supporting controllers to set/get
the RF transmit power level of a node and test specific links between
nodes with a specific RF transmit power level.
【BASIC command class】
Control the roller shutter to be opened or closed after receiving the
BASIC_SET command.
To be opened:
[Command Class Multilevel, Multilevel Set, Value = 0xFF]
To be closed:
[Command Class Multilevel, Multilevel Set, Value= 0x00]
To be the percentage of full opened position:
[Command Class Multilevel, Multilevel Set, Value = 0x01~0x63]
【SWITCH MULTILEVEL command class】
Control the roller shutter to be opened, closed, stopped or be the
percentage of full opened position after receiving the SWITCH
MULTILEVEL command.
To be opened:
[Command Class Multilevel, Multilevel Set, Value = 0xFF]
To be closed:
[Command Class Multilevel, Multilevel Set, Value= 0x00]
To be the percentage of full opened position:
[Command Class Multilevel, Multilevel Set, Value = 0x01~0x63]
To be stopped:
[Command Class Multilevel,
SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE]
【CONFIGURATION command class】
This class is used for setting certain vendor specific configuration
variables. See the following table for configuration variables:
Parameter Name
Size
(byte)
Range Default
value
Description
1
(0x01)
(0x01)
Positioni
ng
Calibratio
n
ng
Calibratio
n
1
0 - 1
0
0: Disable
1: Executing
calibration
1: Executing
calibration
2
(0x02)
(0x02)
External
switch
Protectio
n
switch
Protectio
n
1
0 - 1
0
0: Enable external
switch
1: Disable external
switch
switch
1: Disable external
switch
3
(0x03)
(0x03)
When
the door
is
opened,
set the
delay
time for
automati
c closing.
the door
is
opened,
set the
delay
time for
automati
c closing.
2
0 -
32767
32767
0
0: Disable automatic
closing
1 - 32767: The door
will be closed
automatically in 1 -
32767sec
closing
1 - 32767: The door
will be closed
automatically in 1 -
32767sec
4
(0x04)
(0x04)
When
the door
is open,
set the
delay
time for
automati
c
notificati
on.
the door
is open,
set the
delay
time for
automati
c
notificati
on.
2
0 -
32767
32767
0
0: Disable automatic
notification
1 - 32767: The
notification will be
sent automatically in
1 - 32767sec
notification
1 - 32767: The
notification will be
sent automatically in
1 - 32767sec
5
(0x05)
(0x05)
Set the
operatio
n mode
operatio
n mode
1
0 - 1
0
0: Roller Shutter
1: Venetian
(up/down and slate
rotation)
1: Venetian
(up/down and slate
rotation)
6
(0x06)
(0x06)
Set the
angle of
blinds
angle of
blinds
1
0 - 6
0
Angles of blinds
0:0∘
1:30∘
2:60∘
3:90∘
4:120∘
5:150∘
6:180∘
0:0∘
1:30∘
2:60∘
3:90∘
4:120∘
5:150∘
6:180∘
7
(0x07)
(0x07)
Set the
slats
turning
time
slats
turning
time
1
0 - 127 15
(1.5sec
)
)
0:Disable.
1 - 127: 0.1 - 12.7 sec
1 - 127: 0.1 - 12.7 sec
8
(0x08)
(0x08)
Set the
delay
time to
start the
motor up
to the
blade
delay
time to
start the
motor up
to the
blade
1
0 - 127 0
0:No offset time
1 - 127: 0.1 - 12.7 sec
1 - 127: 0.1 - 12.7 sec
9
(0x09)
(0x09)
Set the
delay
time to
start the
motor
down to
the blade
delay
time to
start the
motor
down to
the blade
1
0 - 127 0
0:No offset time
1 - 127: 0.1 – 12.7 sec
1 - 127: 0.1 – 12.7 sec
10
Set the 1
0 - 100 0
0:Disabled
(0x0A)
power
changed
percenta
ge to
send the
power
report
changed
percenta
ge to
send the
power
report
1 - 100: 1% - 100%
11
(0x0B)
(0x0B)
Set the
time
interval
of
reporting
watts in
seconds
time
interval
of
reporting
watts in
seconds
2
0,
60 -
32767
60 -
32767
300
sec
sec
0:Disable
60 - 32767:
60 - 32767sec
60 - 32767:
60 - 32767sec
12
(0x0C)
(0x0C)
Set the
time
interval
of
reporting
KWH in
seconds
time
interval
of
reporting
KWH in
seconds
2
0,
60 -
32767
60 -
32767
3600
0:Disable
60 - 32767:
60
60 - 32767:
60
- 32767sec
【ASSOCIATION command class】
The device can be set 1 auto-report ID in Group 1.
The device sends an unsolicited command to the configured
destinations when triggered by an event.
Group1:"Lifeline" :
【ASSOCIATION GRP INFO command class】
The purpose of the Association Group Information (AGI) Command
Class is to allow a device to report the capabilities of each
association group supported by the device.
【SWITCH_BINARY command class】
Control the roller shutter to be opened or closed after receiving the
SWITCH BINARY command.
To be opened:
[Command Class SWITCH_BINARY, Set Value = 0xFF]
To be closed:
[Command Class SWITCH_BINARY, Set Value = 0x00]
【METER command class】
The Meter Command Class is intended for Z-Wave enabled devices
capable of reporting energy measurements in addition to any main
functionality or features e.g. an appliance module reporting the
current consumption of the connected load. The Meter command
class not support V1&V2 version. And it will take about 3 seconds to
show the meter report on the request sending device.
【FIRMWARE UPDATE META DATA command class】
Support OTA (On-The-Air) firmware update function.
【COMMAND_CLASS_SECURITY_V1】
【COMMAND_CLASS_SECURITY_2_V1】
This device is a security enabled Z-Wave Plus product that is able to
use encrypted Z-Wave Plus messages to communicate to other
security enabled Z-Wave Plus products.
Product Overview
Product Dimensions