Shanghai Huace Navigation Technology LTD. A01024 Benutzerhandbuch

Seite von 27
 
 
WGS84 Lat/Lon/H, WGS84 X/Y/Z. 
Coordinate: depend on the coordinate format user choose. 
(3) 
Tap 
  ok button at the bottom of New point screen to save the point. 
4.3 Measure Points 
Note:  To  ensure  the  accuracy  of  the  coordinates  measured;  please  perform 
measurements after the rover receiver receives correction data (with correction LED 
flashes once per second) and gets a fixed solution. 
4.4 Measure Points in PDA Mode 
(1) 
In the main menu, tap Survey → tap PT Survey
(2) 
Enter the point name in the input frame on the first row. 
(3) 
Notes:  The  system  will  automatically  increase  the  numeric  component  of  the 
measured point name. 
(4) 
The measured points will be automatically increased from “P1”, by default. 
(5) 
If necessary, enter the feature code in the input frame on the second row. 
(6) 
For [Method] row, click the method follows, and select the right Method for the 
survey from the dropdown list. 
(7) 
Notes: Users can tap Setting icon which is located at upper right to configure the 
settings of each measurement method in the pop-up Survey Option screen. 
(8) 
The auto survey function is available for two measurement modes: Topographic 
PT Mode, Compensate PT Mode. 
(9) 
When untick Auto Survey in the Survey Option screen: 
(10) 
If the settings of the selected measurement method have been changed, click 
left arrow at upper left directly to save the change and go back to the Point Survey 
screen. 
(11) 
Tap   
     button,  hold  the  range  pole  still  and  vertical  until  the  countdown 
timer disappears, and then, move to next point and continue the survey.   
(12) 
To exit the Auto Measure mode, tap 
    button. 
4.5 Point Adjust (Site Calibration) 
Point adjust, also known as “site calibration”, is used to transform WGS-84 coordinates 
into local grid coordinates.