Shanghai Huace Navigation Technology LTD. A01024 Benutzerhandbuch

Seite von 27
 
 
Notes
• General speaking, if a three- or seven-parameter datum transformation has been 
configured for the project, users can skip the site calibration and the coordinates 
measured will be transformed automatically into local grid coordinates. 
• If  a projection and datum transformation have already been specified, users can 
reduce  any  discrepancies  between  the  WGS-84  coordinates  and  the  local  grid 
coordinates by performing a site calibration. 
• To perform the site calibration, users need to measure the control points with GNSS 
receiver first. 
To perform site calibration: 
(1) 
In the main menu, tap Survey → tap Site CAL
(2) 
Tap Add at the lower left corner to add point pair(s). 
(3) 
In the pop-up screen, tap icon located at the same row with Name at the first row 
of GNSS Point section to add the existing GNSS point or key in a GNSS point. 
(4) 
Tap  icon  located  at  the  same  row  with  Name  at  the  first  row  of  Known  Point 
section to add the existing known point or key in a known point. 
 
 
 
(5) 
Choose the method of calibration at the bottom of the screen and click OK to finish 
the chosen for this pair. 
Notes:   
Users  can  determine  whether  this  point  pair  is  involved  in  the  computation  of 
either horizontal or vertical adjustment or both. 
(6) 
Continue the Step 2 to Step 5 to add all the point pairs. 
(7) 
After entering all the existing pairs, go back to Site Calibration screen, choose an 
appropriate Height Fitting Method and click Calculate button. 
Notes
The height fitting methods are “Surface Fitting”, “Best Practice” (by default) and 
“Fixed difference” respectively. For best results, make sure that the control points 
are evenly distributed to the extent of the job area. 
(8) 
Click Application the prompt is “Whether replace the current project parameters 
or not”, choose Yes and apply the result to the whole project. 
Notes:   
Users can log to view plane correction and vertical fitting parameters. Otherwise, 
those are invisible. The default login values of display function are  “admin” for 
Name and “123456” for Password