Advanced Card Systems Limited ACR1281S Benutzerhandbuch

Seite von 57
ACR1281S 
 
 Advanced Card Systems Ltd. 
Page 15 of 56 
 
8.  Bulk-OUT Command 
8.1 HOST_to_RDR_IccPowerOn 
This command is used to activate the ICC and PICC . The ATR will be returned if available in 
response “RDR_to_HOST_DataBlock” Format (See 2.1). 
 
Command Frame Format 
STX 
(0x02) 
Bulk-OUT Header 
(HOST_to_RDR_IccPowerOn) 
Parameters 
Checksum 
ETX 
(0x03) 
1 Byte 
10 Bytes 
0 Byte 
1 Byte 
1 Byte 
 
 
HOST_to_RDR_IccPowerOn Format 
Offset 
Field 
Size 
Value 
Description 
bMessageType 
62h 
 
dwLength 
<LSB .. MSB> 
00000000h 
Message-specific data length 
bSlot 
00h,01h 
00h forPICC interface, 01h for ICC  
bSeq 
00h-FFh 
Sequence number for command 
bPowerSelect 
00h, 01h, 
02h, 03h 
Voltage that is applied to the ICC 
00h – Automatic Voltage Selection 
01h – 5.0 volts 
02h – 3.0 volts 
03h – 1.8 volts 
abRFU 
 
Reserved for Future Use 
 
Note:  The ICC interface must be activated before access contact cards while PICC interface is 
optional.  
Example: Power on PICC slot 
Command: 
02
 
62 00 00 00 00 00 00 00 00 00
 
62 03
 
ACK: 02 00 00 03  
Response:  
02 
80 10 00 00 00 00 00 00 81 00
 
3B 8B 80 01 4A 43 4F 50 33 31 33 36 47 44 54 4C
 
2A 03 
 
8.2 HOST_to_RDR_IccPowerOff  
This command is used to deactivate the ICC. For PICC, it does nothing. 
 
Command Frame Format 
STX 
(0x02) 
Bulk-OUT Header 
(HOST_to_RDR_IccPowerOff) 
Parameters 
Checksum 
ETX 
(0x03) 
1 Byte 
10 Bytes 
0 Byte 
1 Byte 
1 Byte 
 
HOST_to_RDR_IccPowerOff Format 
Offset 
Field 
Size 
Value 
Description 
bMessageType 
63h 
 
dwLength 
<LSB .. MSB> 
00000000h 
Message-specific data length 
bSlot 
00h,01h 
00h forPICC interface, 01h for ICC  
bSeq 
00-FFh 
Sequence number for command 
abRFU 
 
Reserved for Future Use