Advanced Card Systems Limited ACR1281S Benutzerhandbuch

Seite von 57
ACR1281S 
 
 
 Advanced Card Systems Ltd. 
Page 16 of 56 
 
Example: Power off PICC slot 
Command: 
02
 
63 00 00 00 00 00 00 00 00 00
 
63 03
 
ACK: 02 00 00 03  
Response:  
02 
81 00 00 00 00 00 00 00 81 00
 00 03
 
 
8.3 HOST_to_RDR_XfrBlock  
 
This command is used to exchange APDUs between the Host and ACR1281S. 
 
Command Frame Format 
STX 
(0x02) 
Bulk-OUT Header 
(HOST_to_RDR_XfrBlock) 
APDU Commands 
Checksum 
ETX 
(0x03) 
1 Byte 
10 Bytes 
M Bytes 
1 Byte 
1 Byte 
 
HOST_to_RDR_XfrBlock Format 
Offset 
Field 
Size 
Value 
Description 
bMessageType 
6Fh 
 
dwLength 
<LSB .. MSB> 
Message-specific data length 
bSlot 
00h,01h 
00h forPICC interface, 01h for ICC  
bSeq 
00-FFh 
Sequence number for command 
bBWI 
00-FFh 
Used to extend the Block Waiting 
Timeout. 
wLevelParameter  2 
0000h 
 
10 
abData 
Byte 
array 
 
Data sent to the reader. 
Example: Read 256 bytes from PICC slot 
Command: 
02 
6F 05 00 00 00 00 00 00 00 00
 80 B2 00 00 00
 58 03
 
ACK: 02 00 00 03  
Response:  
02
 80 02 01 00 00 00 00 00 81 00 
01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 
11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 
2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 
4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 
6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F 80 81 82 83 84 85 86 87 88 
89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 
A6 A7 A8 A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF 
C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA 
DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6 
F7 F8 F9 FA FB FC FD FE FF 00 90 00
 92 03
 
8.4 HOST_to_RDR_GetSlotStatus 
 
     This command is used to get the status of  ICC, PICC slots. 
Command Frame Format 
STX 
(0x02) 
Bulk-OUT Header 
(HOST_to_RDR_XfrBlock) 
Parameters 
Checksum 
ETX 
(0x03) 
1 Byte 
10 Bytes 
0 Byte 
1 Byte 
1 Byte 
 
 
HOST_to_RDR_GetSlotStatus Format