4 Configuring the V390i 
38 
V290iA User Guide 
control-plane 


line con 0 
 exec-timeout 0 0 
 stopbits 1 
line 1 4 
 exec-timeout 0 0 
 session-limit 1 
 modem InOut 
 no exec 
 transport input telnet 
 transport output telnet 
 escape-character NONE 
 telnet break-on-ip 
 stopbits 1 
line aux 0 
line vty 0 4 
 password vyyo 
 login 

end 
 
Router#   
SCADA Traffic Configuration 
The V390i is designed to interface with asynchronous SCADA devices via serial ports 
Ser0 – Ser3.  This section illustrates the configuration under which SCADA traffic 
transmission traffic was tested in Arcadian Networks’s lab. 
An optional network configuration for transmitting SCADA through the V390i is to use 
TCP encapsulation over Telnet tunneling. Using this method, the router directs the 
Telnet packets to the desired serial port according to the destination TCP port of the 
Telnet connection (4001 is the default port for Serial Port 1 Raw Data, 4002 for port 2, 
and so on). The SCADA master is connected to a router that functions as the Telnet 
caller, and the SCADA device is connected to the V390i, which is the called.  
Once the caller receives serial data, it initiates a permanent TCP connection.  
 
Figure 27: SCADA Traffic Tunneling