Arcadian Networks Inc. V390I Benutzerhandbuch

Seite von 79
 
V290iA User Guide 
53 
6
 Troubleshooting 
This chapter includes: 
„ 
A list of common issues and the troubleshooting actions to be taken when they are 
encountered. The issues are composed of two types: issues that must be dealt with 
on-site, and issues that can be dealt with remotely. 
„ 
The on-site troubleshooting section includes also a list of device status indications, 
as provided by the state of the WiFi interface panel LEDs. 
„ 
Instructions for remote and local Telnet access to the V390i. 
For a description of the V390i LEDs, refer to Chapter 2, Interface Panel LEDs on 
page 49. 
On-site Troubleshooting Issues 
Table 6: On-Site Troubleshooting Issues 
Issue 
Actions 
All LEDs are OFF 
„ 
Check that the power cable is properly connected. 
„ 
Check the power at the cable end connecting to the V390.  
If it is OK:  
„ 
Check whether there is a problem with your electrical 
system. 
„ 
Otherwise, replace the V390i. 
Power is not stable (power LED 
is not steady) 
„ 
Verify that the power supply in use can deliver 5A at the 
required voltage and temperature range.  
„ 
If power supply cannot deliver it – there is a problem 
with your electrical system. 
„ 
Otherwise, replace the V390i.