Baumer Electric AG OIS-W-WR300303 Benutzerhandbuch
Baumer Ident AG
12 / 13
Author: Clemens Zehnder
File: Maintenance-SW.doc Version 3.0 e
4.1.3 Page 3: Operation Mode Settings
Picture 4-3: operation mode settings
Name Description
Range
Default
Remarks
Mmain
main operation mode
0..1
0
0=event driven,1=triggered
Mtxuntrig
transmitter state when not triggered;
for triggered and event driven mode
0..1 1
0=off,1=on
Mbiased biased
mode
0..1
0 0=off,1=on
Mrandom
random mode; ramp timing distributions
0..3
0
0=off, 1=uniform distributed, 2,3=not yet released
MRTm
max. measurements per block
0..255
25
the min measurement block corresponds to
Parameter „Reader Settings: Nequ“.
Also used for triggered mode when random = OFF.
MRNmess number of measurement blocks
1..255 5
MRTdmin
min. random delay
1..65535
5
in ramp durations
1
MRTdlen
range of random delay
1..65535
50
in ramp durations
Mtsleep
sleep time
1..65535
50
in ramp durations
Table 4-1: operation mode settings
1 Ramp duration = 20 ms