File: Maintenance-SW.doc Version 3.0 e     
 
 
Mmain / MTxuntrig 
Operation mode 
Mmain 
MTxuntrig 
Description 
Event Driven Mode  TX 
On 
The  reader (R) always sends out an interrogating signal and the identification 
is always activated. 
Event Driven Mode TX Off 
The  reader (R) sends out an interrogating signal and the identification is 
activated only if  the trigger input is on „1“.  
Triggered Mode TX On 
The  reader (R) always sends out an interrogating signal. But the 
identification starts only if the  reader (R) is triggered. 
Three ways to trigger: 
• 
trigger input on „1“ 
• 
via telegram 
• 
for test purpose via service PC keyboard „t“ 
Triggered Mode TX Off 
The  reader (R) doesn’t send out an interrogating signal on stand by mode. If 
the  reader (R) is triggered it sends out an interrogating signal. After a 
successful identification or after a certain time the  reader (R) returns back to 
stand by mode. 
Three ways to trigger: 
• 
trigger input on „1“ 
• 
via telegram 
• 
for test purpose via service PC keyboard „t“ 
Table 4-2: Mmain / MTxuntrig 