Baumer Electric AG OIS-W-WR300303 Benutzerhandbuch
Baumer Ident AG
13 / 14
Author: Clemens Zehnder
File: Maintenance-SW.doc Version 3.0 e
Mmain / MTxuntrig
Operation mode
Mmain
MTxuntrig
Description
Event Driven Mode TX
On
0
1
The reader (R) always sends out an interrogating signal and the identification
is always activated.
Event Driven Mode TX Off
0
0
The reader (R) sends out an interrogating signal and the identification is
activated only if the trigger input is on „1“.
Triggered Mode TX On
1
1
The reader (R) always sends out an interrogating signal. But the
identification starts only if the reader (R) is triggered.
Three ways to trigger:
•
trigger input on „1“
•
via telegram
•
for test purpose via service PC keyboard „t“
Triggered Mode TX Off
1
0
The reader (R) doesn’t send out an interrogating signal on stand by mode. If
the reader (R) is triggered it sends out an interrogating signal. After a
successful identification or after a certain time the reader (R) returns back to
stand by mode.
Three ways to trigger:
•
trigger input on „1“
•
via telegram
•
for test purpose via service PC keyboard „t“
Table 4-2: Mmain / MTxuntrig
Mbiased
Not yet released!