Intel P4304BTSSFCN Benutzerhandbuch

Seite von 20
Monthly Specification Update 
Enterprise Platforms and Services Marketing 
 
 
11 
26.  The NMI button on front panel does not work as expected    
Problem 
When pressing the NMI button on the front panel the system does not generate 
an Non-Maskable Interrupt. 
Implication  
Cannot create NMI interrupt through the NMI button on front panel. 
Status 
Fixed in BIOS Rev.35  
Workaround       None. 
27.   Consistency Check in S1200BTL/S1200BTS motherboard’s ESRT2 
OpROM Configuration Utility returns error message 
Problem           Consistency Check in S1200BTL/S1200BTS motherboard’s ESRT2 OpROM 
Configuration Utility returns error message 
Implication  
 The screen may pop up message “Error In Reading Sectors To Drive0 ! 
Proceed Anyway (Y/N)?”.  If Y is pressed, the screen may pop up the same 
message after a while. The Consistency Check may not complete 
successfully.  User has to abort the Consistency Check. 
Status 
It is under investigation of why ESRT2 OpROM Configuration Utility has such a 
limitation. 
Workaround 
 In the operating system environment, use Intel
®
 RAID Web Console 2 to 
implement Consistency Check.  The failure to complete Consistency Check 
during ESRT2 OpROM Configuration Utility doesn’t impact normal usage under 
operating system environment. 
28.  There is no driver for Intel® 82579 network card on VMWare ESXi* 5.0, 
VMWare ESXi* 4.1 Update 1 and VMWare* ESX 4.1 Update 1 
Problem
  
There is no driver for Intel
®
 82579 network card on VMWare ESXi* 5.0, 
VMWare ESXi* 4.1 Update 1 and VMWare* ESX 4.1 Update 1 
Implication  
Intel
®
 82579 network card can not be recoginized under VMWare ESXi* 5.0, 
VMWare ESXi* 4.1 Update 1 and VMWare* ESX 4.1 Update 1 
Status 
NA.  
Workaround       None. 
29.  The boot time is 10 mins if using 4k section HDDs 
Problem  
Using the 4K section HDDs in USB port and set it as non boot device, it needs 
10 minute to pass through. It is should be in less than one minutes.