Intel P4304BTSSFCN Benutzerhandbuch

Seite von 20
Monthly Specification Update 
Enterprise Platforms and Services Marketing 
 
12 
Implication  
The boot up time is too long. 
Status 
Fixed in BIOS Rev. 35.  
Workaround       None. 
30.  Unable to get Server Management variables on BTP using SysCfg 
Problem  
Server Management Settings cannot be configured using latest SysCfg Version 
10 Build6 on S1200BTL. 
Implication  
The user can’t change BMC setting by the latest syscfg tool on Intel
®
 Server 
Board S1200BTL. 
Status 
Fixed in BIOS Rev. 35.  
Workaround       None. 
31.  Function key can not work on KVM remote console on S1200BTL board 
Problem  
Function key can not work on KVM remote console on S1200BTL board. 
Implication  
The user can’t enter into BIOS setting from KVM remote console during server 
is booting up. 
Status 
Fixed in BIOS Rev.37.  
Workaround       Enter BIOS setting to set the option “System Boot Timeout” from 0 to 3 
seconds. 
32.  ME downgrade is not supported by IDA and OFU 
Problem  
IDA and OFU can not support ME downgrade. 
Implication  
IDA and OFU doesn’t support ME downgrade from  02.02.00.036 or higher 
version to 02.00.09.032 or lower version. 
Status 
Will fix in the future IDA and OFU release. 
Workaround       None 
33.  When updating BMC in IDA, IDA shows BMC Release version in Hex. E.g: 
1.14 shown as 1.0e 
Problem  
IDA can not show BMC version in decimalization. 
Implication  
IDA only can show BMC release version in Hex when updating BMC by IDA 
tool.