RadioFrame Networks Inc MCSERIESHP10 Benutzerhandbuch
MC-Series High-Power System
System Definition
998--01 Rev X1
RadioFrame Networks, Inc.
CONFIDENTIAL AND PROPRIETARY 21
provides conversion of the 10Base2 connection at the iSC to a 10BaseT connection in
the BIC.
the BIC.
Figure 9 CRTC Ports and Indicators
2.2.1.5 BIC
Ports
Table 3 Ports in the BIC
Card
Port
Description
Front
Ports 1-7 (RJ-45)
not currently used
Port 8 (RJ-45)
Sprint Nextel technician local Ethernet access
BIC CRIC
EIA-232 9-pin serial port
Sprint Nextel technician local serial access
BPC
N/A N/A
Back
Port 1 (RJ-45)
CRTC 1 Port 10BaseT
Port 2 (RJ-45)
AIC ERTM port 4
Port 3 (RJ-45)
CRTC 2 Port 10BaseT (Optional)
Port 4 (RJ-45)
not currently used
Port 5 (RJ-45)
RF Shelf 1 10/100 Port 1
Port 6 (RJ-45)
RF Shelf 2 10/100 Port 1
Port 7 (RJ-45)
RF Shelf 3 10/100 Port 1
Port 8 (RJ-45)
Remote Ethernet connectivity (DNX-1u Ethernet)
5 MHz/1PPS IN
iSC-3 5-MHz/1PPS port
5 MHz/1PPS OUT
not currently used (no terminator required)
ERTM
GPS ANT
not currently used
10Base2 – iSC
ISC-3 10Base2 port
CRTC 1
10BaseT – iSC
BIC ERTM port 1
10Base2 – iSC
ISC-3 10Base2 port
CRTC 2
(Optional)
(Optional)
10BaseT – iSC
BIC ERTM port 1
2.2.1.6 BIC
Indicators
Each card installed in the BIC has a Power LED and a Status LED that indicates timing
synchronization.
synchronization.
Note: The CRIC Status LED represents PLL status. The system will not go active unless
this LED is green.
Each RJ-45 port has an Ethernet link LED that indicates connectivity and an Ethernet
activity LED that indicates Ethernet traffic (Figure 10).
activity LED that indicates Ethernet traffic (Figure 10).